2 - 1
2. INSTALLATION
2. INSTALLATION
CAUTION
Stacking in excess of the limited number of pr oducts is not allowed.
Install the equipment to incombustibles. Instal ling them directly or close to
combustibles will led to a fire.
Install the equipment in a load-bearing place in accordance with this Instruction
Manual.
Do not get on or put heavy load on the equipment to prevent injury.
Use the equipment within the specified environm ental condition range.
Provide an adequate protection to prevent scre ws, metallic detritus and other
conductive matter or oil and other combustib le matter from entering the servo
amplifier.
Do not block the intake/exhaust ports of the ser vo amplifier. Otherwise, a fault may
occur.
Do not subject the servo amplifier to drop im pact or shock loads as they are
precision equipment.
Do not install or operate a faulty servo amplifier.
When the product has been stored for an extende d period of time, consult
Mitsubishi.
2.1 Environmental conditions
Environment Conditions
[]0 to 55 (non-freezing)
Operation [] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature Storage []4 to 149 (non-freezing)
Operation
Ambient
humidity Storage 90%RH or less (non-condensing)
Ambience Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280 ft) above sea level
[m/s2] 5.9 [m/s2] or less
Vibration [ft/s2] 19.4 [ft/s2] or less