Mitsubishi Electronics MSY-D30/36NA installation manual Before Installation, MSZ-D30/36NA

Models: MSZ-D30/36NA MSY-D30/36NA

1 8
Download 8 pages 44.28 Kb
Page 1
Image 1
ENGLISH

ENGLISH

 

 

MSZ-D30/36NA

 

 

SPLIT-TYPE AIR CONDITIONERS

MSY-D30/36NA

INSTALLATION MANUAL

 

JG79A061H01

Required Tools for Installation

 

Phillips screwdriver

5/32 in. (4 mm) hexagonal

 

Level

wrench

 

Scale

Flare tool for R410A

 

Utility knife or scissors

Gauge manifold for R410A

 

3 in. (75 mm) hole saw

Vacuum pump for R410A

 

Torque wrench

Charge hose for R410A

 

Wrench (or spanner)

Pipe cutter with reamer

1. BEFORE INSTALLATION

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

• Be sure to read these safety precautions and instructions.

‡ %HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUH

After reading this manual, be sure to store it with the OPERATING INSTRUCTIONS for future reference.

Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system.

MSZ-D30/36NA WARNING (Could lead to death or serious injury.)

NDo not install the unit by yourself (user).

,PSURSHURULQFRPSOHWHLQVWDOODWLRQFRXOGFDXVH¿UHHOHFWULFVKRFNLQMXU\GXHWR

WKHXQLWIDOOLQJRUZDWHUOHDNDJH&RQVXOWDTXDOL¿HGLQVWDOOHURUWKHGHDOHUIURP whom you purchased the unit.

NFollow the instructions detailed in the installation manual.

 ,QFRPSOHWHLQVWDOODWLRQFRXOGFDXVH¿UHRUHOHFWULFVKRFNLQMXU\GXHWRWKHXQLWIDOO-

ing, or leakage of water.

NInstall the unit securely in a place that can bear the weight of the unit. If the installation location cannot bear the weight of the unit, the unit could fall causing injury.

NNPerform electrical work according to the installation manual and be sure to use

an exclusive circuit. Do not connect other electrical appliances to the circuit.

,IWKHFDSDFLW\RIWKHSRZHUFLUFXLWLVLQVXI¿FLHQWRUWKHUHLVLQFRPSOHWHHOHFWULFDO

ZRUNLWFRXOGUHVXOWLQD¿UHRUDQHOHFWULFVKRFN

NGround the unit correctly.

Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel- ephone ground. Defective grounding could cause electric shock.

NNDo not damage the wires.

 'DPDJHGZLUHVFRXOGFDXVH¿UH

NNBe sure to shut off the main power when setting up the indoor P.C. board or wiring.

Failure to do so could cause electric shock.

N 8VHWKHVSHFL¿HGZLUHVWRVHFXUHO\FRQQHFWWKHLQGRRUDQGRXWGRRUXQLWV$W-

WDFKWKHZLUHV¿UPO\WRDYRLGDSSO\LQJVWUHVVWRWKHWHUPLQDOEORFN

 ,PSURSHUFRQQHFWLRQFRXOGFDXVH¿UH

NN'RQRWLQVWDOOWKHXQLWLQDSODFHZKHUHÀDPPDEOHJDVPD\OHDN

If gas leaks and accumulates around the unit, it could cause an explosion.

NDo not use intermediate connection of the power cord or the extension cord.

Do not connect many devices to one AC outlet.

 ,WFRXOGFDXVHD¿UHRUDQHOHFWULFVKRFN

NN8VHWKHSDUWVSURYLGHGRUVSHFL¿HGSDUWVIRUWKHLQVWDOODWLRQZRUN

7KHXVHRIGHIHFWLYHSDUWVFRXOGFDXVHDQLQMXU\RUOHDNDJHRIZDWHUGXHWRD¿UH an electric shock, the unit falling, etc.

NNWhen plugging the power supply plug into the outlet, make sure that there is no dust, blockage, or loose parts both in the outlet and on the plug. Verify that the power supply plug is completely in the outlet.

NNSecurely attach the electrical cover to the indoor unit and the service panel to the outdoor unit.

If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are

QRWDWWDFKHGVHFXUHO\GXVWZDWHUHWFFRXOGFROOHFWLQWKHXQLWDQGFRXOGFDXVHD¿UHRU an electric shock.

NNWhen installing or relocating the unit, make sure that no substance other than

WKHVSHFL¿HGUHIULJHUDQW 5$ HQWHUVWKHUHIULJHUDQWFLUFXLW

Any foreign substances in the refrigerant circuit can cause abnormal pressure rise or an explosion.

NNDo not discharge the refrigerant into the atmosphere. Check that the refrigerant gas does not leak after installation has been completed. If refrigerant leaks during installation, ventilate the room.

,IUHIULJHUDQWFRPHVLQFRQWDFWZLWKD¿UHKDUPIXOJDVFRXOGEHJHQHUDWHG

,IUHIULJHUDQWJDVOHDNVLQGRRUVDQGFRPHVLQWRFRQWDFWZLWKWKHÀDPHRIDIDQ heater, space heater, stove, etc., harmful gases will be generated.

NNUse appropriate tools and piping materials for installation.

The pressure of R410A is 1.6 times higher than R22. Not using the appropriate tools and materials, or improper installation could cause the pipes to burst causing an injury.

NNWhen pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.

If the refrigerant pipes are disconnected while the compressor is running and the stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high, causing the pipes to burst.

NNWhen installing the unit, securely connect the refrigerant pipes before starting the compressor.

If the compressor is started before the refrigerant pipes are connected and the

stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high, causing the pipes to burst.

NN)DVWHQDÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKLVPDQXDO

,IIDVWHQHGWRRWLJKWDÀDUHQXWFRXOGEUHDNDQGFDXVHUHIULJHUDQWOHDNDJH

NN Install the unit according to national wiring regulations.

If there is dust, blockage, or loose parts on the power supply plug or the outlet, it could

FDXVHHOHFWULFVKRFNRU¿UH,IORRVHSDUWVDUHIRXQGRQWKHSRZHUVXSSO\SOXJUHSODFHLW

SPLIT-TYPE AIR CONDITIONERS CAUTION (Could lead to serious injury when operated incorrectly.)

N Depending on the installation area, install a Ground Fault Interrupt (GFI) circuit

N 'RQRWWRXFKWKHDLULQOHWRUWKHDOXPLQXP¿QVRIWKHRXWGRRUXQLW

breaker.

This could cause injury.

If the Ground Fault Interrupt (GFI) circuit breaker is not installed, an electric shock

N Do not install the outdoor unit where small animals may live.

could occur.

If small animals enter the unit and damage its electrical parts, it could cause a

N Perform the drainage/piping work securely according to the installation

PDOIXQFWLRQVPRNHHPLVVLRQRU¿UH.HHSWKHDUHDDURXQGWKHXQLWFOHDQ

manual.

 

If there is defect in the drainage/piping work, water could drip from the unit, and

 

damage household items.

 

Page 1
Image 1