1-2. SELECTING THE INSTALLATION LOCATION

1-2. SELECTING THE INSTALLATION LOCATION

INDOOR UNIT

‡ :KHUHDLUÀRZLVQRWEORFNHG

Where cool air aspreads over the entire room.

On a rigid wall to reduce the possibility of vibration.

Where it is not exposed to direct sunlight.

Where it can be easily drained.

At a distance 3 ft. (1 m) or more away from a TV and radio. Operation of the air conditioner may interfere with radio or TV reception. An amplifier may be re- quired for the affected device.

In a place as far away as possible from fluorescent and incandescent lights (so the infrared remote control can operate the air conditioner normally).

:KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\

Note:

Install the indoor unit high on the wall where air can dis- tribute over the entire room.

REMOTE CONTROLLER

Where it is convenient to operate and easily visible.

Where children cannot easily touch it.

‡ 6HOHFWDSRVLWLRQDERXWIW P DERYHWKHÀRRU

Check that signals from the remote controller from that position are received by the indoor unit (‘beep’ or ‘beep beep’ receiving tone sounds). Then, attach remote controller holder to a pillar or wall and install wireless remote controller.

Note:

,QURRPVZKHUHLQYHUWHUW\SHÀXRUHVFHQWODPSVDUHXVHG the signal from the wireless remote controller may not be received.

OUTDOOR UNIT

Where it is not overly exposed to strong winds.

‡ :KHUHDLUÀRZLVJRRGDQGGXVWOHVV

Where neighbours are not annoyed by operation sound or hot air.

Where rigid wall or support is available to prevent the increase of operation sound or vibration.

Where there is no risk of combustible gas leakage.

If installing the unit in a location high above the ground, be sure to secure the unit legs.

Where it is at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where re-

FHSWLRQLVZHDN $QDPSOL¿HUPD\EHUHTXLUHGIRUWKH affected device.

Install the unit horizontally.

Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install

DFDQRS\DSHGHVWDODQGRUEDIÀHERDUGV

Note:

It is advisable to make a piping loop near outdoor unit so as to reduce vibration.

‡ )RU LQFUHDVHG HI¿FLHQF\ LQVWDOO WKH RXWGRRU XQLW LQ D location where continuous direct sunlight or excessive water can be avoided as much as possible.

Note:

When operating the air conditioner in low outside tem- perature, be sure to follow the instructions described below.

Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.

To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall and DEDIÀH board on the air outlet side.

Avoid the following places for installation where air conditioner trouble is liable to occur.

‡ :KHUHÀDPPDEOHJDVFRXOGOHDN

Where there is an excessive amount of machine oil in the air.

Salty places such as the seaside.

Where sulfide gas is generated such as a hot spring.

Where there is high-frequency or wireless equipment.

1-3. SPECIFICATIONS

1-3-1. POWER SUPPLY AND INDOOR/OUTDOOR WIRE CONNECTION

Power should be taken from an exclusive branched circuit.

Wiring work should be based on applicable technical standards.

Wiring connections should be made following the diagram.

Securely tighten screws.

Connecting wires and the ground wire

Use solid conductor AWG14 or stranded conductor AWG14.

Use double insulated copper wire with 600 V insulation.

Use copper conductors only.

* Follow local electrical codes.

Power supply cable and ground wire

Use solid or stranded conductor AWG12.

Use copper conductors only.

* Follow local electrical codes.

Note:

When the indoor unit is powered from the outdoor unit, depending on local code, a disconnect switch needs to be installed to a power supply circuit.

(OHFWULFDOVSHFL¿FDWLRQV

MODEL

 

MSY-D30NA

MSY-D36NA

MSZ-D30NA

MSZ-D36NA

 

 

 

 

 

 

 

INDOOR UNIT

 

 

 

 

 

Power supply

 

208/230, 1, 60

 

(V, PHASE, Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Circuit Ampacity

(A)

1.0

 

 

 

 

 

 

 

 

Fan motor (F.L.A.)

(A)

0.76

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

 

 

 

 

Power supply

 

208/230, 1, 60

 

(V, PHASE, Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Fuse size

(A)

25

 

(time delay)

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Circuit Ampacity

(A)

21

 

 

 

 

 

 

 

 

Fan motor (F.L.A.)

(A)

0.93

 

 

 

 

 

 

 

 

Compressor

(R.L.A)

(A)

16

 

 

 

 

 

 

 

(L.R.A)

(A)

20

 

 

 

 

 

 

 

 

 

 

Control voltage

 

Indoor unit - Remote controller: (Wireless)

 

Indoor unit - Outdoor unit: DC12-24 V (Polar)

 

 

 

 

 

 

 

 

 

 

1-3-2. REFRIGERANT PIPES

To prevent condensation, insulate the two refrigerant pipes.

Refrigerant pipe bending radius must be 4 in. (100 mm) or more.

INDOOR UNIT CAUTION

%HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVV WDEOHRQWKHULJKW ([FHVVLYHLQVXOD- tion may cause incorrect installation of the indoor unit, and too little insulation may cause condensate to form.

‡ 7KHXQLWKDVÀDUHGFRQQHFWLRQVRQERWKLQGRRUDQGRXWGRRUVLGHV

Remove the valve cover from the outdoor unit, then connect the pipe.

Refrigerant pipes are used to connect the indoor and outdoor units.

Be careful not to crush or over bend the pipe in pipe bending.

Refrigerant adjustment... If pipe length exceeds 25 ft. (7.5 m), additional refrigerant

(R410A) charge is required.

(The outdoor unit is charged with refrigerant for pipe length up to 25 ft. [7.5 m])

 

Outside

Minimum

 

Insulation

 

 

 

wall thick-

 

 

 

Pipe

diameter

 

thickness

 

Insulation material

ness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inch (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For liquid

3/8 (9.52)

 

0.0315 (0.8)

5/16 (8)

 

 

Heat resistant foam

 

 

 

 

 

 

 

 

 

 

 

SODVWLF6SHFL¿F

For gas

5/8 (15.88)

0.0394 (1.0)

5/16 (8)

 

 

 

 

gravity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe length

 

 

 

 

100 ft. (30 m) max.

 

 

 

 

 

 

 

 

 

 

 

 

 

Height difference

 

 

50 ft. (15 m) max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of bends

 

 

 

 

10 max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 25 ft. (7.5 m)

 

 

 

No additional charge is re-

 

 

 

 

 

 

 

 

quired.

Pipe length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exceeding 25 ft. (7.5 m)

 

Additional charge is required.

 

 

 

 

 

 

 

(Refer to the table below.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant to be added

 

MSZ-D30/36NA

 

 

2.96 oz. each 5 ft. (55 g/m)

 

 

 

 

 

 

 

 

 

MSY-D30/36NA

 

 

1.08 oz. each 5 ft. (20 g/m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 