4-2. TEST RUN
Emergency operation switch (E.O. SW)

4-2. TEST RUN

1)Insert power supply plug into the power outlet and/or turn on the breaker.

2)Press the E.O. SW once. Test run will be performed

for 30 minutes. If the left operation indicator light blinks every 0.5 seconds, inspect the indoor/outdoor unit con- necting wire (A). After the test run, emergency COOL mode (75ºF [24ºC] COOL) will start.

3)To stop operation, press the E.O. SW several times until all LED lamps turn off. Refer to operating instruc- tions for details.

Checking the remote (infrared) signal reception

Press the ON/OFF button on the remote controller and listen for an audible indicator from the indoor unit. Press the ON/OFF button again to turn the air conditioner off.

Once the compressor stops, the restart preventive device operates so the compres- sor will not operate for 3 minutes to protect the air conditioner.

4-3. AUTO RESTART FUNCTION

This product is equipped with an auto restart function. When the power supply is cut off during operation, such as during blackouts, the function automatically starts opera- tion in the previous setting once the power supply is resumed. (Refer to the operating instructions for details.)

Caution:

After test run or remote signal reception check, turn off the unit with the E.O. SW or the remote controller before turning off the power supply. If this

procedure is not performed, the unit will automatically begin operation when power supply is resumed.

To the user

After installing the unit, explain to the user about auto restart function.

If auto restart function is unnecessary, it can be deactivated. Consult the service representative to deactivate the function. Refer to the service man- ual for details.

4-4. EXPLANATION TO THE USER

Using the OPERATING INSTRUCTIONS, explain to the user how to use the

DLUFRQGLWLRQHU WKHUHPRWHFRQWUROOHUUHPRYLQJWKHDLU¿OWHUVSODFLQJRUUHPRY- ing the remote controller from the remote controller holder, cleaning methods, precautions for operation, etc.)

Recommend that the user read the OPERATING INSTRUCTIONS carefully.

5. RELOCATING THE UNIT / MAINTENANCE

5-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY

Removal procedure (Fig. 1, 2)

1)Remove the three screws that attach the panel assembly.

2)Open the front panel.

3)Remove the two screws that attach the panel assembly.

 5HPRYHWKHSDQHODVVHPEO\%HVXUHWRUHPRYHLWVERWWRPHQG¿UVW

Installation procedure (Fig. 3, 4)

1)Point the horizontal vane slightly downward.

2)Attach the bottom of the panel assembly under the horizontal vane.

3)Fit in the top of the panel assembly.

4)Fit in the bottom of the panel assembly and tighten it using screws.

5)Push the section of the front panel marked by the arrows to close the front panel se- curely.

5-2. REMOVING THE INDOOR UNIT

Remove the bottom of the indoor unit from the installation plate. (Fig. 1, 2)

• Remove the panel assembly. (Refer to 5-1)

‡ ,QVHUWÀDWVFUHZGULYHUVLQWRWKHVTXDUHKROHVDWWKHOHIWDQGULJKWERWWRPRIWKHLQGRRU unit and push them up; the bottom of the indoor unit goes down and the hooks are released.

*1 Remove the screw.

*2 Remove the tab of corner box from the indoor unit, and pull the corner box. *3 Pull the indoor unit to remove.

5-3. PUMPING DOWN

When relocating or disposing of the air conditioner, pump down the system following the procedure below so that refrigerant is not released into the atmosphere.

1)Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit.

2)Fully close the stop valve on the liquid pipe side of the outdoor unit.

3)Close the stop valve on the gas pipe side of the outdoor unit almost completely so

that it can be easily closed fully when the pressure gauge shows 0 MPa [Gauge] (0 lbf/in.2 [0 kgf/cm2]).

4)Start the emergency COOL operation.

To start the emergency operation in COOL mode, disconnect the power supply plug and/or turn off the breaker. After 15 seconds, connect the power supply plug and/or turn on the breaker, and then press the E.O. SW once. (The emergency COOL op- eration can be performed continuously for up to 30 minutes.)

5)Fully close the stop valve on the gas pipe side of the outdoor unit when the pressure gauge shows 0.05 to 0 MPa [Gauge] (approx. 7.25 to 0 lbf/in2 [0.5 to 0 kgf/cm2]).

6)Stop the emergency COOL operation.

To stop operation, press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions for details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1

 

 

 

 

 

 

 

 

Fig. 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3

Horizontal vane Fig. 4

 

 

Corner box

Push Lower

Square hole

Fig. 1

Fig. 2

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Page 8
Image 8
Mitsubishi Electronics MSZ-D30/36NA Relocating The Unit / Maintenance, Test Run, Auto Restart Function, Pumping Down