Initialization (Reset)/Functional Restriction Setting
You can return the settings to their
1.After pressing SIZE for about 5 seconds, press , , , and in that order.
FUNCTION | 1/1 | ||
|
|
| |
| ALL RESET |
|
|
| ADJUSTMENT LOCK | OFF | |
| UNLOCKED | ||
| OSD DISPLAY | ON | |
| LED | ON | |
| TEMPERATURE ALERT | LED | |
| STATUS ALERT | OFF | |
|
|
| END…[MENU] |
2.Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press , select the resetting method, and then press
MENU .
After initialization, turn the main power switch off and then back on.
ALL RESET1 ....Resets all the settings to the factory
default settings.
ALL RESET2 ....Returns all settings to the factory default
settings except for the following items: LAN SETUP,
ADJUSTMENT LOCK
You can disable operations on the monitor and the remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power
on/off and FUNCTION.
2.........Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not even power on/off).
Specifies whether to allow control via
OSD DISPLAY
Hides/shows menus.
The FUNCTION screen cannot be hidden.
LED
Specifies whether to light power LEDs.
TEMPERATURE ALERT
Selects the notification method for an abnormal temperature.
OFF | Do not notify about an abnormal |
| temperature. |
OSD & LED .. | When an abnormal temperature is |
| detected, the power LED flashes in red |
| and green alternately and the screen |
| displays a message: TEMPERATURE. |
LED | When an abnormal temperature is |
| detected, the power LED flashes in red |
| and green alternately. |
| |
STATUS ALERT | |
Selects the notification method for a hardware error. | |
OFF | Do not notify about the error. |
OSD & LED .. | When a hardware error is detected, the |
| power LED flashes in red and the screen |
| displays a message: STATUS [xxxx]. |
LED | When a hardware error is detected, the |
| power LED flashes in red. |
|
|
3. Press MENU to return to the normal screen.
TIPS
•When both abnormal temperature and hardware error are detected, the hardware error notification overrides.