036-21544-001 Rev. B (1103)

3 STANDARD OPERATING DATA

PKH INDOOR UNITS WITH PUGH OUTDOOR UNITS

MODELS

 

 

PKH18FK

PKH24FK

PKH30FK

PKH36FK

Item

 

 

Unit

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

V

208/230

208/230

208/230

208/230

 

 

 

 

 

 

 

 

 

 

 

 

Circuit

Frequency

 

Hz

60

60

60

60

60

60

60

60

 

 

 

 

 

 

 

 

 

 

 

Total Input

 

kW

1.79

1.51

2.54

2.18

3.01

2.56

3.47

3.19

 

 

 

 

 

 

 

 

 

 

 

Electrical

Indoor Fan Current

 

A

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

 

 

 

 

 

 

 

 

 

 

 

Booster Heater Current

 

A

--

7.6/8.4

--

7.6/8.4

--

7.6/8.4

--

7.6/8.4

 

 

 

 

 

 

 

 

 

 

 

Outdoor Fan Current (FLA)

 

A

0.5

0.5

0.5

0.5

1.4

1.4

1.3

1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Current (230v)

 

A

7.6

6.2

10.6

8.9

12.5

10.1

17.3

16.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensing Pressure

 

PSIG

275

207

274

222

277

234

265

258

 

 

 

 

 

 

 

 

 

 

 

 

Circuit

Suction Pressure

 

PSIG

81

55

73

56

79

54

74

58

 

 

 

 

 

 

 

 

 

 

 

Discharge Temperature

 

°F

174

138

187

191

185

157

187

149

 

 

 

 

 

 

 

 

 

 

 

Condensing Temperature

 

°F

109

51

110

87

110

79

106

80

Refrigerant

 

 

 

 

 

 

 

 

 

 

 

 

Suction Temperature

 

°F

68

40

62

46

68

43

65

33

 

 

 

 

 

 

 

 

 

 

Compressor Shell Bottom Temperature

°F

146

103

103

137

148

97

122

74

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Pipe Length

 

FT.

25

25

25

25

25

25

25

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Charge

 

-

3 lbs

8 oz

5 lbs

11 oz

4 lbs

15 oz

5 lbs

5 oz

 

 

 

 

 

 

 

 

 

 

 

 

 

Intake Air Temperature

DB

°F

80

70

80

70

80

70

80

70

 

 

 

 

 

 

 

 

 

 

 

Side

WB

°F

67

60

67

60

67

60

67

60

 

 

 

 

 

 

 

 

 

 

 

 

Discharge Air Temperature

DB

°F

61

95

58

103

49

100

57

106

Indoor

 

 

 

 

 

 

 

 

 

 

WB

°F

59

--

56

--

57

--

55

--

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed

 

RPM.

1490

1490

1490

1490

 

 

 

 

 

 

 

 

 

 

 

Airflow (High)

 

CFM

640

640

910

885

 

 

 

 

 

 

 

 

 

 

 

 

Side

Intake Air Temperature

DB

°F

95

47

95

47

95

47

95

47

 

 

 

 

 

 

 

 

 

 

WB

°F

--

43

--

43

--

43

--

43

 

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed

 

RPM.

1050

1050

1100

850

 

 

 

 

 

 

 

Airflow (High)

 

CFM

1750

1950

2650

3250

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

BTU/H

17900

17400

23400

23000

29600

30000

34200

35000

 

 

 

 

 

 

 

 

 

 

 

 

SHF

 

 

--

0.77

--

0.68

--

0.72

--

0.68

--

 

 

 

 

 

 

 

 

 

 

 

 

Mitsubishi Electronics 2003

5

Page 5
Image 5
Mitsubishi Electronics PUGH42AYB PKH Indoor Units with Pugh Outdoor Units, Models PKH18FK PKH24FK PKH30FK PKH36FK