Indicators

The projector has three indicators each of which shows the working condition of the projector.

The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your dealer.

POWER indicator

LAMP indicator

TEMP indicator

 

 

LAMP

TEMP

 

 

ZOOM/

 

 

 

 

FOCUS

 

 

 

 

VOLUME

 

 

 

 

 

 

 

 

 

COMPUTER

VIDEO

MENU

 

ENTER

AUTO

MUTE

POSITION

 

Normal condition

POWER LAMP

TEMP CONDITION

Notes

Steady

Off

Stand-by

 

Off

 

red

 

 

 

 

 

Lamp stand-by (about for 1 minute)

The power button cannot be used to switch

Steady

Blinking

Off

ON and OFF

green

green

 

 

 

The POWER is ON. (Normal condition)

 

Steady

Steady

Off

 

green

green

 

 

Abnormal condition

POWER LAMP TEMP CONDITION

POSSIBLE SOLUTIONS

Steady

Steady

Blinking

Unusual temperature

The ventilation slits or air filter is clogged with

green

green

red

 

dust or debris.

 

 

 

 

 

 

 

The fan has stopped due to an impediment.

Steady

Off

Steady

The room temperature is too high.

red

 

red

• The filter is dirty.

 

 

 

Lamp duration warning. (Lightning duration total

Steady Blinking Off about 1, 500 hours.When the POWER is ON.)

green green/red

Steady

Blinking

Off

Lamp duration warning. (Lightning duration total

about 1, 500 hours.When the POWER is OFF.)

red

red

 

Remove the object from the ventilation slits.

Pull out the power plug andremove the object. If you cannot, consult your dealer.

Relocate the projector to a cooler place.

Clean the filter.

Replace the lamp.

Exchange with a new lamp if the same problem recurs.

Steady

Steady

Off

Lamp duration warning. (Lightning duration total

 

about 2,000 hours.)

 

red

red

 

 

 

 

 

The lamp or filter cover is not closed.

Close the cover correctly.

Blinking

Off

Off

 

 

green/red

 

 

 

 

 

Steady

Steady

Abnormal.

Contact your dealer.

 

 

 

Blinking

or

or

 

 

 

 

 

 

green/red

 

 

 

 

 

Blinking

Blinking

 

 

EN – 26