Air flow direction adjustment procedure

Adjusting up/down air flow direction

Up/down direction can be adjusted with the AIRFLOW button on the remote control. Each time when you press this button the mode changes as follows:

(Air scroll)

(SWING)

(flap stopped)

Change to AIRFLOW mode.

Air scroll

In COOL and DRY operation

In HEAT operation

SWING FLAP

Stops at this position

Stops at this position

for 5 seconds.

for 5 seconds.

Flap moves up and down continuously.

Thick line

 

 

: moves quickly

Thick line

 

 

: moves quickly

 

 

 

 

Thin line

 

 

: moves slowly

Thin line

 

 

: moves slowly

NOTE

If the room temperature control (thermostat) switches to the heating mode or if the defrosting operation is on, the blow flap changes automatically to a horizontal position.

If the heating operation has just started and the room temperature is still low, it may take a while before the flap moves to the above sway operation angle.

The flap may stop at the tilted down-blow position during the “sway operation” in the heating mode.

MEMORY FLAP (FLAP STOPPED)

When you press the AIRFLOW button once while the flap is operating, it stops swinging at an angle.Since this angle is memorized in the micro-computer, the flap will automatically be set at this angle when the next operation is started.

Recommended angle of the flap when stopping

HEAT

(Slant forward COOL, DRY

(Horizontal

 

blowing)

blowing)

DANGER

Avoid constant airflow to the body for hours on end.

CAUTION

When in COOL or DRY operation, do not operate for hours on end with the air flow blowing straight down. Otherwise, condensation may appear on the outlet grill and drip down.

Do not try to adjust the flaps by hand, as the control angle may change or the flap may not close properly.

Adjusting left/right air flow direction

Adjust the direction by moving the left/right air flow fin by hand.

CAUTION

Please stop the air conditioner when adjusting the air flow direction.

Emergency run operation

The ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.

Operation program

 

 

 

OPERATION MODE

:

AUTO

FAN SPEED

:

AUTO

AIR FLOW

:

AUTO

Operation starts by pressing the ON/OFF button; it stops if you press the button again.

Unit ON/OFF button