Indicators

The projector has three LED Indicators which shows the working condition of the projector.

The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your dealer.

POWER indicator

LAMP indicator

TEMP indicator

 

AUTO POSITION

POWER

MUTE

 

COMPUTER

LAMP

SOURCE

VOLUME

VIDEO

TEMP

MENU

 

ENTER

Normal condition

POWER LAMP

TEMP CONDITION

Notes

Steady

Off

Stand-by

 

Off

 

red

 

 

 

 

Lamp stand-by (about for 1 minute)

The power button cannot be used to switch

 

Steady

Blinking

Off

ON and OFF

green

green

 

 

 

The POWER is ON. (Normal condition)

 

Steady

Steady

Off

 

green

green

 

 

Abnormal condition

POWER LAMP TEMP CONDITION

POSSIBLE SOLUTIONS

 

 

Steady

Steady

Blinking

green

green

red

 

 

Steady

Off

Blinking

red

 

red

Unusual temperature

The ventilation slits or air filter is clogged with dust or debris.

The room temperature is too high.

The filter is dirty.

Remove the object from the ventilation slits.

Relocate the projector to a cooler place.

Clean the filter.

 

 

The protection circuit is working or lamp is abnormal.

 

Off

 

Steady

Blinking

 

red

green

 

 

 

 

Lamp duration warning. (Lightning duration total

 

Off

Steady

Blinking

about 1, 500 hours.When the POWER is ON.)

green

green/red

 

 

 

Lamp duration warning. (Lightning duration total

 

Off

Steady

Blinking

about 1, 500 hours.When the POWER is OFF.)

red

red

 

Wait until the LAMP indicator is turned off, then press the POWER button.

Replace the lamp.

Replace the lamp.

Exchange with a new lamp if the same problem recurs.

Steady

Steady

Off

Lamp duration warning. (Lightning duration total

 

about 2,000 hours.)

 

red

red

 

 

 

 

The lamp or filter cover is not closed.

Close the cover correctly.

 

 

Blinking

Off

Off

 

 

green/red

 

 

 

 

 

Steady

Steady

Abnormal.

Contact your dealer.

 

 