Loosen and remove screw | Temperature |
| extension tab |
| Temperature extension |
Turn fully CCW | Spindle |
| |
| Retaining nut pin |
RE-CALIBRATION PROCEDURE
1.To
2.Turn the temperature extension counter- clockwise until it stops.
3.Loosen and remove the screw in the center of the temperature extension by turning it counterclockwise.
4.Carefully remove the temperature extension without turning it or the spindle behind it. You have now accessed the spindle.
5.To increase the temperature, rotate the spindle
6.Replace the temperature extension, positioned fully
7.Turn the flow handle
Increase temperature | Decrease temperature |
Spindle with temperature extension in place
| Spindle w/ temperature |
Retaining nut pin | extension removed |
8.After the water temperature has stabilized, check the temperature. This will be the new maximum temperature. If the temperature is not suitable, remove the temperature extension as described above and repeat this procedure to further adjust the water temperature.
9.When the maximum temperature is acceptable,
10.Refer to “Attach Temperature Knob” instructions on how to
6