Connecting directly to an unregulated

CHECKING GAS PRESSURE AND CONNECTING REMOTE RECEIVER

WARNING

 

The heater gas inlet connection is 3/8" NPT at the valve. The

Connecting directly to an unregulated

inlet is located on left side of stove. Remove front control plate

 

 

to better access the inlet.

 

propane/L.P.G. tank can cause an

 

 

 

explosion.

When tightening up the joint to the valve, hold the valve securely

 

 

with a wrench to prevent movement.

Test all gas joints from the gas meter to the heater valve for

leaks using a gas analyzer or soap and water solution after completing connection. DO NOT USE AN OPEN FLAME.

Check the gas pressure with the appliance burning and the control set to HIGH.

 

MILLIVOLT CONTROL (FIGURE 5)

Test Port “OUT”

The valve regulator controls the burner pressure which should

 

be checked at the pressure test point.

 

If outlet pressure is low, check inlet pressure against data plates

 

or manual.

 

Turn captured slotted screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “OUT” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.

Figure 5 - Pressure Test Point Location

Milli-Volt Control

NOTE: Remove control panel to access gas valve and ignitor battery module.

CONNECTING REMOTE RECEIVER

1.Remove cover on control panel to show opening for remote receiver. See Figure 6.

2.Cut cable to length (approximately 12") for placement in the fireplace.

3.Strip back 1/4" of the insulation from both ends of each wire.

4.Connect two .25 female connectors to the wires at one end of the cable.

5.Insert the opposite ends of the wires into the receiver wire terminals and tighten the screws.

6.Connect the connectors to the two .25" male connectors located on the left side when facing the unit (Figure 6). Do not let the wire touch the grate or burners.

7.Slide remote receiver in the opening of control panel. Use two screws provided to attach remote receiver to the control panel. See Figure 6.

8.Replace Cover. See Figure 6.

NOTE: Do not place remote in combustion chamber.

Remote Receiver

Cover

Figure 6 - Installing Remote Receiver