Monessen Hearth DESIGNER SERIES manual FOR UNITS WITH 6CN AND 6CLP CONTROLS INSTALLED

Models: DESIGNER SERIES

1 26
Download 26 pages 41.43 Kb
Page 19
Image 19
FOR UNITS WITH 6CN AND 6CLP CONTROLS INSTALLED

OPERATING INSTRUCTIONS

18

 

 

FOR UNITS WITH 6CN AND 6CLP CONTROLS INSTALLED

 

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.

B.

THIS APPLIANCE HAS A PILOT WHICH MUST BE LIT BY HAND WHILE FOLLOWING THESE INSTRUCTIONS EXACTLY. BEFORE LIGHTING SMELL ALL AROUND THE APPLIANCE AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON

THE FLOOR.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL

THE FIRE DEPARTMENT.

C. USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS

CONTROL KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT PUSH IN OR TURN BY HAND, DO NOT TRY TO REPAIR IT. CALL A QUALIFIED SERVICE TECHNICIAN. FORCE OR

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.

ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.

D. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN

UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE

TECHNICIAN TO INSPECT THE APPLIANCE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS

CONTROL WHICH HAS BEEN UNDER WATER.

LIGHTING INSTRUCTIONS

WHEN LIGHTING AND RELIGHTING, THE GAS KNOB CANNOT BE TURNED FROM PILOT TO OFF UNLESS THE KNOB IS

DEPRESSED.

1. STOP! READ THE SAFETY INFORMATION ON THE FIRST

LABEL.

2. TURN OFF ALL ELECTRICAL POWER TO THE APPLIANCE.

3. TURN GAS KNOB CLOCKWISE IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL TO OFF.

ON

OFF

 

T

 

PI LO

GAS KNOB "OFF"

D. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN 4. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. THEN
SMELL FOR GAS, INCLUDING NEAR THE FLOOR. IF YOU

SMELL GAS, STOP! FOLLOW "B" IN THE SAFETY INFOR- MATION ON THE FIRST LABEL. IF YOU DON'T SMELL

GAS GO TO THE NEXT STEP.

5. IF APPLIANCE IS EQUIPPED WITH HI-LO ADJUSTMENT

6. FIND PILOT LOCATED IN FRONT OF THE MIDDLE LOG.

PILOT

GENERATOR

PIEZO ELECTRODE

THERMOCOUPLE

7. TURN GAS KNOB COUNTERCLOCKWISE

TO PILOT.

8.DEPRESS AND HOLD GAS KNOB WHILE LIGHTING THE PILOT WITH THE PUSH BUTTON IGNITOR. KEEP KNOB FULLY DEPRESSED FOR ONE MINUTE, THEN RELEASE.

IF PILOT DOES NOT CONTINUE TO BURN REPEAT STEPS 3 THRU 7.

9.WITH PILOT LIT TURN GAS KNOB COUNTERCLOCKWISE

TO ON.

10.IF EQUIPPED WITH REMOTE ON-OFF SWITCH MAIN BURNER MAY NOT COME ON WHEN YOU TURN THE

VALVE TO ON OR HIGH. REMOTE SWITCH MUST BE IN THE ON POSITION TO IGNITE BURNER.

11.TURN ON ALL ELECTRICAL POWER TO THE APPLIANCE.

TO TURN OFF GAS TO APPLIANCE

1. TURN OFF ALL ELECTRICAL POWER TO THE APPLIANCE

2. PUSH IN GAS CONTROL KNOB SLIGHTLY AND TURN

IF SERVICE IS TO BE PERFORMED.

CLOCKWISE

TO OFF. DO NOT FORCE.

068058

53D9019. Rev 3 11/07