Monessen Hearth DESIGNER SERIES manual Safety Checklist, Don’ts

Models: DESIGNER SERIES

1 26
Download 26 pages 41.43 Kb
Page 20
Image 20

SAFETY CHECKLIST

19

 

 

Correct installation and safe operation of this appliance require, but are not limited to the following:

Do's:

1.Do use this appliance only on type of gas it is designed, certified and equipped.

2.Do install this appliance and all gas piping according to local codes, or in the absence of local codes, according to the current National Fuel Gas Code, ANSI Z223.1 latest edition.

3.Do disconnect or isolate the appliance during supply line pressure testing.

4.Do locate the appliance out of traffic patterns as much as possible.

5.Do keep in mind that some furniture materials such as vinyl or plastic may deform at the temperatures near this appliance and must be kept at greater distances.

6.Do use joint compound (pipe dope) on threaded joints of gas piping that is resistant to the action of liquified petroleum gas.

7.Do include a manual shutoff valve and union ahead of the controls so that the controls and appliance may be removed for servicing if necessary.

8.Do use only ground joint unions in gas piping.

9.Do include a drip leg in the gas supply connection to the appliance.

10.Do use only soap-water solution or liquid gas leak solution when checking for leaks in the gas plumbing. Never use matches, candles or other ignition sources when checking for leaks.

11.Do connect the appliance only to an agency listed vent system.

12.Do adjust the air shutter as required to produce the proper flame as described in this manual.

13.Do keep the area around the appliance clear and free from combustible materials, gasoline and other flammable vapors and liquids.

14.Do follow the lighting and operation procedures given in this manual.

15.Do periodically inspect the pilot and burner flame as described in the maintenance section of this manual.

16.Do clean the appliance as specified in the maintenance section of this manual.

17.Do provide electrical grounding of appliance in accordance with local codes and/or the National Electric Code ANSI NFPA 70 latest edition.

18.Do inspect the entire venting system at least once a year and replace all parts that show evidence of damage or deterioration.

Don’ts

1.Don’t modify or alter the appliance cabinet (jacket) in any way.

2.Don’t use this appliance on any gas other than the type for which it is equipped. The type of gas for which the appliance was equipped at the factory is stamped on the rating plate located on the bottom of the appliance.

3.Don’t install the appliance in areas where gasoline or any flammable liquid or any explosive materials may be used or stored.

4.Don’t obstruct the flow of air for combustion and ventilation into or away from the appliance at any time.

5.Don’t use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

6.Don’t operate this appliance without proper electrical grounding according to local codes or the National Electric Code ANSI NFPA 70 latest edition.

7.Don’t operate this appliance without a proper vent.

8.Don’t connect this appliance to a chimney flue serving a solid fuel burning appliance.

9.Don’t use thermostats or automatic burner cycling devices.

53D9019. Rev 3 11/07