GENERAL INSTALLATION INFORMATION AND LOCATION OF FIREBOX
MINIMUM HEARTH DIMENSIONS
| ||
A | 22⅜" | 25⅞" |
B | 12¾" | 15" |
C | 28⅝" | 32½" |
D | 28" | 30¼" |
E | 23¼" | 25⅝" |
Figure 2 - Minimum Hearth Dimensions
LOCATION OF FIREBOX
Carefully select the best location for installation of your
•Clearance to side wall, ceiling, woodwork and windows. See “Clearances/Height Requirements” on page 8. Minimum clearances to combustibles must be maintained.
•Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air registers for forced air furnaces / air conditioners, windows or doors.
•Installation must provide adequate ventilation and combustion air.
•DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM.
• Location should be out of high traffic or windy or |
|
| |
Figure 3 - Location of Firebox | |||
drafty areas. | |||
|
|
•DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM FRONT OF HEATER.
•Never obstruct the front opening of the
•Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
•Do not install in the vicinity where gasoline or other flammable liquids may be stored. The
26D4721 | 7 |