GENERAL INSTALLATION INFORMATION AND LOCATION OF FIREBOX

MINIMUM HEARTH DIMENSIONS

 

LCUF32-F

LCUF36C-R

A

22⅜"

25⅞"

B

12¾"

15"

C

28⅝"

32½"

D

28"

30¼"

E

23¼"

25⅝"

Figure 2 - Minimum Hearth Dimensions

LOCATION OF FIREBOX

Carefully select the best location for installation of your vent-free firebox. The following factors should be taken into consideration:

Clearance to side wall, ceiling, woodwork and windows. See “Clearances/Height Requirements” on page 8. Minimum clearances to combustibles must be maintained.

Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air registers for forced air furnaces / air conditioners, windows or doors.

Installation must provide adequate ventilation and combustion air.

DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM.

• Location should be out of high traffic or windy or

 

 

Figure 3 - Location of Firebox

drafty areas.

 

 

DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM FRONT OF HEATER.

Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation air.

Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.

Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox must be kept clear and free from these combustible materials.

26D4721

7

Page 7
Image 7
Monessen Hearth LCUF32-F dimensions General Installation Information and Location of Firebox, Minimum Hearth Dimensions