Monessen Hearth MCUF42D SERIES USING OPTIONAL AK-4OUTSIDE AIR KIT, Left Side of, Insulation Ring

Models: MCUF42D SERIES

1 20
Download 20 pages 48.71 Kb
Page 17
Image 17
Left Side of

USING OPTIONAL AK-4 OUTSIDE AIR KIT

The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model AK4 combustion air kit.

MODEL AK-4 COMBUSTION AIR ASSEMBLY

1.Remove the cover plate from the 4" outlet opening location on the left or right outside of the fireplace.

2.Place the insulation ring between the AK-4 starting collar and fire- place wall.

WARNING

DO NOT remove the cover if the outside air will not be connected.

3.Place the starting collar (4") into the hole on the side of fireplace. Fasten it in place with the four sheet metal screws provided. See Figures 21 and 22.

Note: The air starting collar extends through the fireplace outer wrap. When the air starting collar is securely attached, it will form a seal against the fireplace wall.

4. Attach outside duct to starting collar with duct clamp or screws. See Figure 22.

 

Left Side of

Insulation Ring

 

 

 

 

 

Fireplace

 

Screws

 

Air Starting

 

AK-4 Starting

 

 

 

 

 

 

 

Collar

 

 

Collar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duct

 

 

Sheet

 

 

 

 

 

 

Meal

 

 

 

 

 

 

Screws

 

 

 

 

 

 

Shorter End

 

 

Left Side of

 

 

 

 

 

Fireplace

 

 

 

of Air Starting

 

Figure 22- Attaching Outside Duct

 

 

Collar

 

Figure 21 - Attaching Outside Air Starting Collar

 

 

to Starting Collar

 

 

 

 

 

 

and Insulation Ring to Left Side of Fireplace

 

6" Diameter

 

 

 

 

 

 

 

 

5. Cut a 6-inch diameter opening for model AK-4 in the outside

Hole

 

Screw

 

 

 

wall covering where the outside vent is to be located. See

 

 

 

 

Figure 23.

 

 

 

 

Nail

6. Select and cut a piece of duct long enough to attach to the

 

 

 

 

Holes

 

fireplace and stick out at least 3" beyond the face of the wall

 

 

 

 

 

 

 

to which the AK-4 inlet air vent will be attached. See Figure

Duct

 

 

 

22.

 

Extending

 

 

 

 

 

 

 

WARNING

 

 

 

3"min.

 

 

Use FP-4 U duct for maximum efficiency

 

 

AK-4 Inlet

 

 

and safety. Do not use a combustible

 

 

Air Vent

Screws

 

duct. Always use UL Listed Class 0 or

 

 

 

 

 

 

 

 

 

1 duct material.

 

Figure 23 - Combustion Air Assembly for

 

 

 

 

 

Model No. AK-4

Continued

 

 

 

 

 

 

26D4720

17

Page 17
Image 17
Monessen Hearth MCUF42D SERIES USING OPTIONAL AK-4OUTSIDE AIR KIT, Left Side of, Insulation Ring, Fireplace, Air Starting