TROUBLESHOOTING

Parlor Vent Free Fireplace

WARNING

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights, but flame

1. Control knob not fully pressed in.

1.

Press in control knob fully.

goes out when control knob is

2. Control knob not pressed in long

2.

After ODS/pilot lights, keep control

released.

 

enough.

 

knob pressed in for 30 seconds.

 

3.

Manual shutoff valve not fully open.

3.

Fully open manual shutoff valve.

 

4.

Thermocouple connection loose at control

4.

Hand tighten thermocouple connec-

 

 

valve.

 

tion until snug, then tighten 1/4 turn

 

 

 

 

more.

 

5.

Pilot flame not touching thermocouple,

5a.Contact local gas company.

 

 

which allows thermocouple to cool, caus-

5b.Clean pilot with vacuum cleaner.

 

 

ing pilot flame to go out. This problem could

 

 

 

 

be caused by either low gas pressure, or a

 

 

 

 

dirty or partially clogged ODS/pilot.

6.

Replace thermocouple.

 

6.

Thermocouple damaged.

 

7.

Control valve damaged.

7.

Replace control valve.

 

 

 

 

 

Burner does not light after ODS/

1.

Burner orifice is clogged.

1.

Clean orifice.

pilot is lit.

2.

Burner orifice diameter is too small.

2.

Replace burner orifice.

 

3.

Inlet gas pressure is too low.

3.

Contact qualified service person.

 

 

 

 

Burner backfires during com-

1. Manifold pressure is too low.

1.

Contact local gas company.

bustion.

2.

Burner orifice is clogged.

2.

Clean burner or replace burner ori-

 

 

 

 

fice.

Slight smoke or odor during

1. Burner orifice is clogged or damaged.

1.

Clean burner or replace burner ori-

initial operation.

2.

Burner is damaged.

 

fice.

 

3.

Gas regulator defective.

2.

Replace burner.

 

 

 

3.

Replace gas regulator.

Logs appear to smoke after initial operation.

1.Vapors from paint or curing process of logs.

2.Vapors or smoke continue after heater has run with damper or window open for several hours.

1.Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours.

2.Log heater is intended to be smoke- less. Turn OFF heater and call quali- fied service person.

Heater produces a whistling 1.

Turning control knob to HIGH position

noise when burner is lit.

when burner is cold.

2.

Air in gas line.

3. Dirty or partially clogged burner orifices.

1.Turn control knob to LOW position and let warm up for a minute.

2.Operate burner until air is removed from line. Have gas line checked by local gas company.

3.Clean burner or replace burner ori- fice.

No gas to pilot.

1. LP-regulator shut down due to inlet pres-

 

sure too high.

1.Verify LP tank regulator is installed and set at 11" to 13" w.c.

2.Replace regulator on heater.

90D0093

27

Page 27
Image 27
Monessen Hearth PL20 operating instructions Troubleshooting

PL20 specifications

The Monessen Hearth PL20 is an exemplary addition to any home, designed for both aesthetics and functionality. This versatile gas fireplace offers an ideal solution for those seeking warmth and charm without the hassle of traditional wood-burning options. The PL20 is noted for its sleek contemporary design, making it a perfect fit for various home styles, whether modern or classic.

One of the standout features of the Monessen Hearth PL20 is its powerful heating capability. With an impressive heating capacity of up to 20,000 BTUs, it effectively warms up spaces ranging from small to medium-sized rooms, providing comfort during the coldest months. The adjustable flame height allows users to customize their heating experience, creating an ambiance that suits their mood while maintaining efficiency.

The PL20 is equipped with advanced technologies that enhance its performance and user convenience. The innovative piezo igniter ensures a quick and reliable start, eliminating the need for matches or kindling, making it incredibly user-friendly. Additionally, the remote control capability allows homeowners to easily adjust the flame and temperature settings from the comfort of their seating area.

Safety is a top priority in the design of the PL20. It includes an automatic shut-off feature that activates if it detects any irregularities in operation, ensuring peace of mind for families. The unit also comes with a protective screen, which adds an extra layer of safety, particularly in homes with children and pets.

In terms of aesthetics, the Monessen Hearth PL20 does not disappoint. It offers a variety of trim options and decorative media, allowing users to personalize their fireplace to reflect their taste. The realistic log set or decorative stones create a lifelike appearance, enhancing the overall visual appeal of the unit.

Additionally, the PL20 boasts energy efficiency that resonates with eco-conscious homeowners. By using natural gas or propane, it minimizes environmental impact while providing consistent heating. Its sealed combustion system draws air from outside, ensuring that indoor air quality remains unaffected during operation.

Overall, the Monessen Hearth PL20 is a remarkable fireplace that combines modern functionality with classic charm. Its advanced technologies, safety features, and customizable aesthetics make it an excellent choice for anyone looking to enhance their home's warmth and style. Whether used for family gatherings or quiet nights in, the PL20 promises to deliver comfort and elegance in every setting.