FLOOR PROTECTION
If this fireplace is installed on a combustible floor, the floor area 16 inches in front of, and 8 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth extension may be either minimum
The insulation used in the H1652 hearth extension has a thermal conductivity (K Factor) of .43. If you do construct a hearth extension equivalent to the H1652, be sure the insulation you use has enough compressive strength to support the weight of the covering materials and persons standing on it, and insulating qualities equal to or better than the ˚" covering provided by the H1652.
FIGURE 10
8"
MIN.
16"
MIN.
8"
MIN.
16"
MIN.
6"
MIN.
BRICK OR STONE
HEARTH EXTENSION
(52" LONG MIN.)
FIREPLACE
HEARTH
FIREPLACE
HEARTH
PLATFORM (PLATFORM MAY
EXTEND UNDER HEARTH
EXTENSION IF DESIRED.)
DO NOT PLACE HEARTH
MATERIALS ABOVE OPENING
OF FIREPLACE.
METAL SAFETY STRIP
ALTERNATE BRICK OR STONE HEARTH EXTENSION SHOWN WITHOUT THE OPTIONAL MLK36 LOUVER KIT INSTALLED ON THE FIREPLACE.
6"
MIN.
BRICK OR STONE HEARTH EXTENSION
DO NOT PLACE HEARTH MATERIAL
ABOVE OPENING OF FIREPLACE.
METAL SAFETY STRIP
(52" LONG MIN.)
8"
MIN.
16"
FIREPLACE
HEARTH
ALTERNATE BRICK OR STONE HEARTH EXTENSION SHOWN WITH THE OPTIONAL MLK36 LOUVER KIT INSTALLED ON THE FIREPLACE.
MIN.
6"
MIN.
BRICK OR STONE HEARTH EXTENSION
(52" LONG MIN.)
PLATFORM (PLATFORM MAY
EXTEND UNDER HEARTH
EXTENSION IF DESIRED.)
METAL SAFETY STRIP
DO NOT BLOCK ANY LOUVERED OPENINGS
10