CHIMNEY CAP CHASE INSTALLATION

The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installation should be planned so that either an 18-inch or 36-inch chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.

CAUTION: Be careful around electrical wires to avoid the electrical shock hazard of contacting the wires with the metal chimney components.

NOTE: When two fireplace chimneys are terminated above the same chase, the centers of the chimney caps should be at least 24 inches apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use. Additional spacing between caps or staggering the height of the caps will further lessen the likelihood of this occurring.

1.Extend the chimney sections until the top of the chimney is not more than 10 inches below the top of the chase.

2.Center the hole in the chase cover over the chimney. The chase cover overhang should be lanced, formed over the chase and secured with nails. This prevents water from seeping under the chase cover. If two or more chase covers are to be used on the same chase, they should be soldered together to form two watertight seams.

3.Place the inlet air telescope inside the hole in the chase cover and lower it down into the mating pipe of the chimney until the flange on the telescope section rest on the flange of the chase cover. Note: All telescoping sections should extend a minimum of three inches inside the mating chimney pipes.

4.Install the SCL or SQ8 chimney cap by placing the cap into the matching duct telescope and flue telescope of the last chimney section as shown by Figure 23. Lower the cap until the brackets on the bottom of the chimney cap rests on the raised flange of the flat flashing, punch or drill 1/8 inch diameter holes in the raised flange of the flat flashing, and fasten the cap to the flashing with the No. 8 screws provided.

5.Check all parts of the chimney and chimney cap to assure that no parts have been damaged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney and chimney cap has a rust-protective coating but the cut edges of the parts are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney cap should be detergent-washed and painted with galvanized primer paint.

FIGURE 23

CHIMNEY CAP SUPPORT

SCL OR SQ8 CHIMNEY CAP DESIGN INCORPORATES LONGER

DUCT AND FLUE PIPE FOR CHASE TYPE INSTALLATION.

BRACKETS. 3 PLACES.

 

 

FLAT FLASHING OR CHASE COVER WITH 11-1/4" MIN. DIA. HOLE

SCREW

10" MAXIMUM SPACE BETWEEN

 

MAINTAIN CHIMNEY

CHIMNEY SECTION AND CHASE COVER.

 

SYSTEM AIR SPACE

 

CLEARANCES TO

 

COMBUSTIBLES

 

ABOVE ROOF LINE.

3" MINIMUM OVERLAP

 

INLET AIR TELESCOPE

 

CHASE

 

ROOF

21

53D9033. Rev 1 03/03

Page 21
Image 21
Monessen Hearth SWB400I instruction manual Chimney CAP Chase Installation

SWB400I specifications

The Monessen Hearth SWB400I is a versatile and efficient gas fireplace insert designed to enhance the aesthetic appeal and comfort of any home. It is an ideal solution for homeowners looking to upgrade their existing wood fireplace or transform an unutilized hearth into a modern, functional heating source.

One of the key features of the SWB400I is its impressive heating capacity. This insert can produce up to 40,000 BTUs, effectively warming areas of approximately 1,500 square feet. This makes it a powerful option for larger living spaces, ensuring consistent comfort during the colder months. The unit is equipped with a patented dual burner system that provides a realistic flame presentation while maximizing efficiency. Its efficient design means that users can enjoy a warm ambiance without worrying about excessive fuel consumption.

The Monessen SWB400I also boasts an advanced electronic ignition system, ensuring reliable starts every time. This technology eliminates the need for cumbersome matches or lighter fluid, making it user-friendly. In addition, the fireplace insert includes a built-in thermostat control, allowing homeowners to maintain the desired temperature with ease.

Another notable characteristic of the SWB400I is its customizable aesthetic options. Homeowners can choose from a variety of decorative fronts, including traditional and contemporary styles, to seamlessly integrate the insert into their home’s decor. The unit also features multiple media options, such as logs or contemporary glass pebbles, providing a personalized touch to the fireplace’s appearance.

Safety is a top priority with the SWB400I. It is equipped with a safety pilot system that automatically shuts off the gas supply in case of an emergency, ensuring peace of mind for users. Additionally, the fireplace insert comes with a removable safety screen that prevents accidental contact with the hot glass surface.

In summary, the Monessen Hearth SWB400I is a powerful, stylish, and efficient gas fireplace insert that combines innovative technology with customizable features. Its ability to produce significant heat, easy-to-use ignition system, and various aesthetic options make it a desirable addition to any home. Whether you're looking to increase your home's warmth or enhance its visual appeal, the SWB400I is an excellent choice for homeowners seeking quality and performance.