Motorola 6806800C44B manual SaAmfSUsperSIRankTabl

Models: 6806800C44B

1 54
Download 54 pages 37.4 Kb
Page 19
Image 19

Compliance ReportIntroduction

Table 1-2 Compliance Table - Availability Service, SAI-AIS Volume 2: Availability Management Framework (continued)

 

Section

Description

Support

Notes

 

 

 

 

 

 

3.7.4

N-Way Redundancy

Yes

SIs based on saAmfSIRank

 

 

Model

 

are assigned to SU based on

 

 

 

 

saAmfSUsperSIRankTabl

 

 

 

 

e till all the SIs are assigned

 

 

 

 

an active assignment. Then

 

 

 

 

each SI based on

 

 

 

 

saAmfSIRank is assigned

 

 

 

 

fully to SUs as standby before

 

 

 

 

the next SI is assigned as

 

 

 

 

standby. When an SU fails

 

 

 

 

and the system is in a

 

 

 

 

degraded state, AvSv may

 

 

 

 

ignore the

 

 

 

 

saAmfCompNumMaxActive

 

 

 

 

Csi attribute of a component

 

 

 

 

and assign more active

 

 

 

 

assignments than the

 

 

 

 

permitted number. This policy

 

 

 

 

has been adopted to maintain

 

 

 

 

service continuity for as many

 

 

 

 

SIs as possible even when

 

 

 

 

the system is in a degraded

 

 

 

 

state.

 

 

 

 

 

 

3.7.5

N-Way Active

Yes

AvSv assigns an SI to SU

 

 

Redundancy Model

 

only after the SI with better

 

 

 

 

saAmfSIRank is fully

 

 

 

 

assigned.

 

 

 

 

 

 

3.7.6

No Redundancy Model

Yes

 

 

 

 

 

 

 

3.7.7

The Effect of

Yes

 

 

 

Administrative

 

 

 

 

Operations on Service

 

 

 

 

Instance Assignments

 

 

 

 

 

 

 

 

3.8

Component Capability

Yes

 

 

 

Model and Service

 

 

 

 

Group Redundancy

 

 

 

 

Model

 

 

 

 

 

 

 

 

3.9

Dependencies Among

Yes

Constituent sub-sections that

 

 

SIs, Component Service

 

are only partially supported

 

 

Instances, and

 

or not supported are

 

 

Components

 

mentioned below. Note that

 

 

 

 

the rest of the sub-sections

 

 

 

 

are fully supported.

 

 

 

 

 

 

3.9.1.1

Dependencies Between

No

 

 

 

SIs when Assigning a

 

 

 

 

Service Unit Active for a

 

 

 

 

Service Instance

 

 

 

 

 

 

 

 

3.9.1.2

Impact of Disabling a

No

 

 

 

Service Instance on the

 

 

 

 

Dependent Service

 

 

 

 

Instances

 

 

 

 

 

 

 

 

 

 

 

 

Availability Service Programmer’s Reference (6806800C44B)