Table 3-3 lists environmental requirements for the Gigabit Ethernet/82543
PMC Module.
Table 3-3. Environmental Requirements
Characteristic Specification
Temperature range
(at sea level)
Operating : 0°C to 55°C (32°F to 158°F)
Nonoperating : -40°C to 85°C (-40°F to 185°F)
Temperature
change
Operating : ±0.5°C (33°F) per minute
Nonoperating : ±1.0°C (34°F) per minute
Air flow 200 linear feet per minute (LFM)
Relative humidity Operating : 5% to 95% @ 40°C (104°F) to 55°C (131°F)
— noncondensing
Nonoperating : 5% to 95% @ 40°C (104°F) to 55°C
(131°F) — noncondensing
Altitude Operating : -300 m to +3000 m
Nonoperating : -300 m to +13000 m
Shock Operating : 5 G / 11 ms halfsine — applied once in either
direction of three orthogonal axes
Nonoperating : 15 G / 11 ms halfsine — applied once in
either direction of three orthogonal axes
Vibration Operating : 10 to 15 Hz, 2 mm amplitude — 15 to
150 Hz, 2G
Nonoperating : 10 to 15 Hz, 5 mm amplitude — 15 to
150 Hz, 5G
Free fall Operating : 100 mm / 3 axis
Nonoperating : 1200 mm / all edges and corners
Radiated emissions FCC Class A, CISPR-22 Class A (dated 1998), CISPR-
24 (dated 1998), CE Mark Class A, UL/cUL Recognized
Component