4DIAGNOSTICS
1.When in the OOB Receiver Status Diagnostic, press the MENU button on the remote control to enter the frequency selection mode. The OSD displays a new “MAN FREQ” line at the bottom of the screen, which indicates the last known carrier frequency. At this point, if desired, the frequency change mode can be exited by pressing the MENU key a second time.
2.Use the UP/DOWN channel or cursor keys on the remote control to scroll through all 10 frequencies until the desired new OOB frequency is found. The new frequency selections will appear on the “MAN FREQ” line of the OSD.
3.When the desired new frequency has been selected, press the SELECT key on the remote control to start the search. The manual frequency search will last up to 40 seconds. On the OSD, the “MAN FREQ” line of text will be cleared, the “HUNT MODE” will display “FIX” to indicate a search on a fixed frequency, and the “OOB FREQ” field will change to the frequency being searched for.
4.If the frequency is found with the proper EMM Provider ID, the OSD “LKC” field will change to display the new frequency.
5.If after 40 seconds the frequency search is not successful, the product will perform a warm reset.
6.To abort a search without waiting the 40 seconds, the POWER key on the remote control can be pressed to cause an immediate warm reset.
In-Band Status
This diagnostic displays the
39