Motorola XPR 8300 Electrical Connections, Power Supply Connections, AC Input Power Connection

Models: XPR 8300

1 40
Download 40 pages 7.85 Kb
Page 27
Image 27

Chapter 4 Electrical Connections

After the MOTOTRBO Repeater has been mechanically installed, electrical connections must be made. This involves making the following connections:

AC power cord, and

antenna coaxial cables

Figure 4-1shows the position of the various connectors and connections on the rear panel of the repeater.

TX CONNECTOR

RX CONNECTOR

POWER SUPPLY ON/OFF SWITCH

REAR

ACCESSORYMAIN FAN

CONNECTOR

Rx

Tx

GND

GROUND SCREW

POWER

BATTERY SUPPLY FANETHERNET CONNECTOR

BACKUP

CONNECTOR

AC LINE CORD CONNECTOR

Figure 4-1Locations of Connectors on the Rear Panel of the Repeater

4.1Power Supply Connections

4.1.1AC Input Power Connection

!Do NOT apply AC power to the repeater at this time. Make sure that the circuit breaker associated with the AC outlet is turned to OFF.

C a u t i o n

NOTE: The AC source must be installed near the equipment and must be easily accessible.

Each repeater ships with a 2.438 m (8 feet) 3-conductor line cord that connects the repeater to a 110/120/220/240 VAC source. Figure 4-1shows the location where the AC line cord connects to the repeater. Insert the 3-prong plug into a 110/120/220/240 VAC grounded outlet.

If an alternate line cord is required, obtain a suitable line cord, with fittings approved by the safety testing agency in the end-use country, from a certified electrical parts supplier.