MPC User Manual Rev 0D 11

Notices

Notices
The following notices apply to MPC.

CSA NOTICE

Each MPC unit has been tested by a Canadian Standards Association (CSA) inspector and found to
comply with the special Inspection Requirements of Electrical Equipment. More specifically, this
equipment has been tested for Dielectric strength up to 1000 VAC. The supplied AC electric cord is
also approv ed and must be used with this equipment at all times. The primary fuse rating must be
strictly adhered to as lab elled on the rear of the unit ne ar the fuse holder. Each MP C unit must have the
CSA approved label attached on the rear of the unit.

CAUTION!

1. This device incorporates circuitry to abso rb most s tatic disc harges . However , severe sta tic sh ock
may cause inaccurate operation of the unit. Use anti-static precautions where possible.
2. This device is a precision instrument. Although it is designed for rugged operating conditions, it
performs best when handled with care.
3. The MPC can accept an input supply voltage in the range 100 to 240 VAC. This may not be the
same range as other NovAtel products with which you are familiar. Operating the MPC below 100
VAC causes the unit to suspend operation. An input voltage above 240 VAC may physically
damage the unit.
4. Drawing more than the specified maximum current (1.5 amp) may cause the internal fuse to
interrupt the current. Restoring normal o peratio n will require replacing the fuse.