Mr. Heater MHT 45 owner manual Burner Does Not Light, Burner Does Not Stay Lit

Models: MHT 45

1 24
Download 24 pages 51.43 Kb
Page 21
Image 21
BURNER DOES NOT LIGHT

BURNER DOES NOT LIGHT

Possible Cause

Try This….

Air in the gas line.

Purge gas lines.

 

 

Improper gas inlet pressure.

Check gas inlet pressure at the 1/8” NPT plugged tap. Gas inlet

pressure should be as follows:

 

 

Natural Gas: 5.0”w.c. min.; 10.5” max.

 

LP Gas: 11”w.c. min.; 13.0” max.

 

If gas inlet pressure does not meet inlet pressure requirements

 

contact the gas company.

 

 

Gas valve does not open.

Check for 24V across valve terminals.

 

Check Shutoff On Valve.

 

IF NO: Check wiring between the ignition module and the valve.

 

Repair/replace wires as required. If wiring is OK, replace ignition

 

module. IF YES: Replace gas valve.

 

 

Low gas outlet pressure.

Check gas manifold pressure. Measure manifold pressure at the

 

 

pressure tap on the gas valve.

 

Check gas manifold pressure. Measure manifold pressure at the

 

pressure tap on the gas valve. Natural Gas: 4.0” w.c. LP Gas: 10.0”

 

w.c. If manifold pressure does not meet requirements, adjust valve

 

outlet pressure with the adjustment screw on the valve. NOTE:

 

Proper inlet gas pressure must be verified before performing outlet

 

pressure testing.

BURNER DOES NOT STAY LIT

Possible Cause

Try this…..

Damaged wires between DSI module and electrode.

Replace wires as required.

 

 

Faulty DSI module

Replace DSI module.

 

 

Damaged Electrode

Replace Electrode

 

 