MultiModemZPX User Guide

3 Remote Configuration

Chapter 3 - Remote Configuration

Remote configuration is a network management tool that allows you to configure MT5634ZPX and MT5634ZBA modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote modem for maintenance or troubleshooting as if you were on site.

Basic Procedure

The following steps are valid regardless of whether the connection is established by the local or the remote Multi-Tech modem.

Note: For this procedure, the remote computer must be running, and a communication program must be ready for a data connection, which will be indicated by a lighted TR indicator on the front of the modem.

1.Establish a data connection with a remote MT5634ZPX or MT5634ZBA modem.

2.Send three remote configuration escape characters followed by AT and the setup password, and press ENTER. Example: %%%ATMTSMODEM. You have four tries to enter the correct password before being disconnected. If the password is correct, the remote modem responds with OK.

3.Type AT commands to configure the remote modem.

4.When you have finished configuring the remote modem, save the new configuration by typing AT&W0 and pressing ENTER.

5.Type ATO and press ENTER to exit remote configuration. You can now break the connection in the normal way.

Setup

Multi-Tech modems are shipped with a default setup password (MTSMODEM). Because anyone who has the User Guide knows the default setup password, you should change the password and possibly also the remote configuration escape character.

To Change the Setup Password

1. Open a data communications program such as HyperTerminal or PhoneTools.

2.In the terminal window, type AT#SMTSMODEM (or MTSMODEM password with xxxxxxxx) and press ENTER. password is correct, and ERROR if it is wrong.

AT#Sxxxxxxxx if you have replaced the The modem responds with OK if the setup

3.To change the password, type AT#S=xxxxxxxx, where xxxxxxxx stands for the password, and then press ENTER. The password can include any keyboard character, and can be up to eight characters long. The modem responds with OK.

CAUTION: Passwords are case-sensitive. The next time you enter the password, it must be in the same case as you set it up.

4.The new password is saved automatically. You can now either enter more AT commands or exit the data communications program. The next time you wish to set up the modem, you must use the new password.

15