PS9600 Power Supply User Guide
6CommPlete Communications Server
Introduction
This chapter describes how to install the PS9600 power supply into a CommPlete Communication Server
CC9600 chassis. This equipment should be installed only by a qualified service per son.
Pre-Installation Notes
All installation must be done by a qualified service person.
Warning: Interconnection directly, or by way of other apparatus, of ports marked SAFETY
WARNING see instructions for use with ports marked or not so marked may produce hazardous
conditions on the network. Advice should be obtained from a competent engineer before such a
connection is made.
Warning: Ports that are connected to other apparatus are defined as SELV. To ensure conformity to
EN 41003, ensure that these ports are only connected to the same type on the other apparatus.
To reduce emissions, be sure to use blanking plates to cover empty slots i n the CC9600 chassis.
Installation Procedure
1. Unpack the PS9600 assembly from its packaging and save the packaging for possible fut ure use.
Perform a visual inspection of the PS9600. If you are concerned about it s condition, call Technical
Support for instructions.
2. Make sure the PS9600 power switch is in the off (O) position.
3. Remove the cover plate on the CC9600 if necessary. The PS9600 is hot-swappable.
4. Holding the PS9600 by the front panel and bottom corners, place the PS9600 into the open power
supply slot. Make sure that the top rails on the PS9600 mate prope rly with the plastic guides in the
CC9600.
5. Slowly slide the PS9600 into the CC9600 chassis until you feel the PS9600s conne ctors mate with the
CC9600s connectors.
6. Tighten the PS9600s retaining screws.
7. Turn the PS9600 power switch on to the on (I) position.
8. Observe the PS9600 outputs good LED. If it is not lit, see Chapter 4. If it is lit, pr oceed with normal
CommPlete Communications Server operation.
9. After you turn on the power supplies, you should check the 5 Voutput. See page 10 for details. The
supplies can be re-checked as part of your regular system maintenance.