NEVER grab or touch a live power cord with
wet hands , the POWER
CORD
possibility exists (POWER ON)
of electrical shock, electrocution, and even death!
WET
HANDS

DCA-125SSJU SERIES — RULES FOR SAFE OPERATION

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator.Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

.

DANGER:

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

DANGER:

CAUTION:

Never use damaged or worn cables when connecting equipment to the generator. Make sure power

c o n n e c t i n g

cables are securely connected to the

Radiator

DO NOT touch or open any of the below mentioned components while the generator is running. Always allow sufficient time for the engine and generator to cool before performing maintenance.

generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator and electrical shock.

DANGER:

DANGER:

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the “OFF” position when contact with the output terminals is required. There exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even death!

1.Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.

2.Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant to gush out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.

3.Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper

amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

DCA-125SSJU SERIES (STANDARD)— PARTS AND OPERATION MANUAL— REV. #4 (06/03/03) — PAGE 11

Page 11
Image 11
Multiquip manual DCA-125SSJU Series Rules for Safe Operation, Radiator

DCA-125SSJU specifications

The Multiquip DCA-125SSJU is a robust and reliable diesel generator that stands out in the construction and rental markets. Designed to provide consistent power, this generator is ideal for various applications ranging from industrial construction sites to outdoor events. The DCA-125SSJU boasts a powerful 125 kVA output, making it suitable for both small and large power needs.

One of the prominent features of the DCA-125SSJU is its advanced engine technology. It is powered by a reliable and fuel-efficient Yanmar diesel engine. This engine not only ensures longevity but also optimizes fuel consumption, allowing operators to save on running costs without compromising performance. With a robust design, the Yanmar engine guarantees excellent cold start capability, making it dependable even under challenging weather conditions.

The generator's sound attenuation is also noteworthy. Encased in a sound-attenuated enclosure, the DCA-125SSJU operates at a noise level that makes it suitable for use in residential areas or environments with strict noise regulations. This feature enhances the generator's versatility, as it can be employed in various settings without disturbing nearby activities.

Multiquip has incorporated several safety features into the DCA-125SSJU, including automatic shutdown systems that activate in the event of low oil pressure or overheating. This proactive approach helps safeguard the engine and prolongs its lifespan. Additionally, the generator is equipped with a heavy-duty, weatherproof frame, ensuring durability and protection against the elements.

User-friendly control features make the DCA-125SSJU easy to operate. The generator includes an intuitive digital control panel that provides essential information such as voltage output, frequency, and run time. This accessibility allows operators to monitor performance and adjust settings as necessary.

Portability is another significant advantage of the DCA-125SSJU. With easily transportable dimensions, it can be efficiently moved to various job sites. Its sturdy wheels and lifting points further enhance mobility, making it a practical solution for temporary power needs.

In summary, the Multiquip DCA-125SSJU is a high-performance diesel generator, combining power, efficiency, and portability with advanced technology and user-friendly features. Its reliability and versatility make it an excellent choice for contractors, event organizers, and anyone in need of dependable power supply. Whether facing the demands of a construction site or hosting an outdoor function, the DCA-125SSJU ensures you’ll never be left in the dark.