DCA-125SSJU SERIES — GENERATOR SHUT-DOWN PROCEDURE

Shutdown Procedure - Ignition Switch (Up to S/N 7500507)

To shutdown the generator use the following procedure:

1.Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 45 to the "OFF position".

2.Place the engine throttle control in the “LOW” position (Figure 71).

Shutdown Procedure - Engine Controller (S/N 7500508~)

To shutdown the generator use the following procedure:

1.Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 45 to the "OFF position".

2.Place the engine speed switch in the “LOW” position (Figure 73).

Figure 71. Engine Throttle Control (Low)

3.Let the engine cool by running it for 3-5 minutes with no load applied.

4.Turn the Ignition Key Switch (Figure 72) to the “OFF“ position.

Figure 73. Engine Speed Switch (Low)

3.Let the engine cool by running it for 3-5 minutes with no load applied.

4.Place the Auto-Off/Reset-Manual switch (Figure 74) to the OFF/Reset position.

Figure 72. Engine Ignition Switch (Stop)

Figure 74. Off/Manual Auto Switch (Off)

 

5. Remove all loads from the generator.

Emergency Shutdown Procedure - Ignition Switch (Up to S/N 7500507)

1.To shut-down the engine in the event of an emergency, switch the MAIN, GFCI and LOAD (Figure 61) circuit breakers to “OFF” position.

2.Turn the ignition switch key to the “STOP” position (Figure 72).

5.Verify that the all status LED on the MPEC display (Figure 68) are "OFF" (not lit).

6.Remove all loads from the generator.

Emergency Shutdown Procedure - Engine Controller (S/N 7500508~)

1.To shut-down the engine in the event of an emergency, switch the MAIN, GFCI and LOAD (Figure 45) circuit breakers to “OFF” position.

2.Place the Auto-Off/Reset-Manual switch (Figure 74) to the “OFF/Reset“ position.

CAUTION:

NEVER stop the engine suddenly except in an emergency. DO NOT use the emergency stop switch a as method of shutting down the generator.This switch is ONLY to be used in the event of an emergency.

PAGE 46 — DCA-125SSJU SERIES (STANDARD) — PARTS AND OPERATION MANUAL — REV. #4 (06/03/03)

Page 46
Image 46
Multiquip manual DCA-125SSJU Series Generator SHUT-DOWN Procedure, Shutdown Procedure Ignition Switch Up to S/N

DCA-125SSJU specifications

The Multiquip DCA-125SSJU is a robust and reliable diesel generator that stands out in the construction and rental markets. Designed to provide consistent power, this generator is ideal for various applications ranging from industrial construction sites to outdoor events. The DCA-125SSJU boasts a powerful 125 kVA output, making it suitable for both small and large power needs.

One of the prominent features of the DCA-125SSJU is its advanced engine technology. It is powered by a reliable and fuel-efficient Yanmar diesel engine. This engine not only ensures longevity but also optimizes fuel consumption, allowing operators to save on running costs without compromising performance. With a robust design, the Yanmar engine guarantees excellent cold start capability, making it dependable even under challenging weather conditions.

The generator's sound attenuation is also noteworthy. Encased in a sound-attenuated enclosure, the DCA-125SSJU operates at a noise level that makes it suitable for use in residential areas or environments with strict noise regulations. This feature enhances the generator's versatility, as it can be employed in various settings without disturbing nearby activities.

Multiquip has incorporated several safety features into the DCA-125SSJU, including automatic shutdown systems that activate in the event of low oil pressure or overheating. This proactive approach helps safeguard the engine and prolongs its lifespan. Additionally, the generator is equipped with a heavy-duty, weatherproof frame, ensuring durability and protection against the elements.

User-friendly control features make the DCA-125SSJU easy to operate. The generator includes an intuitive digital control panel that provides essential information such as voltage output, frequency, and run time. This accessibility allows operators to monitor performance and adjust settings as necessary.

Portability is another significant advantage of the DCA-125SSJU. With easily transportable dimensions, it can be efficiently moved to various job sites. Its sturdy wheels and lifting points further enhance mobility, making it a practical solution for temporary power needs.

In summary, the Multiquip DCA-125SSJU is a high-performance diesel generator, combining power, efficiency, and portability with advanced technology and user-friendly features. Its reliability and versatility make it an excellent choice for contractors, event organizers, and anyone in need of dependable power supply. Whether facing the demands of a construction site or hosting an outdoor function, the DCA-125SSJU ensures you’ll never be left in the dark.