DCA-125SSJU SERIES — PRE-SETUP

Circuit Breakers

To protect the generator from an overload, a 3-pole, 300 amp, main circuit breaker is provided to protect the UVW output terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload.Three 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the "OFF" position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 33) on the dipstick. See Table 11 for proper selection of engine oil.

Figure 33. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Volvo Engine Owner's Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

zAPI Service Classification CH-4

zAPI Service Classification CG-4

zAPI Service Classification CF-4

zACEA Specification E3

zACEA Specification E2

Table 11. Recommended Motor Oil

Fuel Check

DANGER:

Fuel spillage on a hot! engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER! smoke around or near the generator.

Refilling the Fuel System

The DCA150SSVU genset may (if equipped with a trailer or skid) have a double fuel tank system (Figure 34), which consists of an internal generator fuel tank, and a trailer mounted fuel tank. It is also possible the genset can be equipped with a skid mounted fuel tank (Figure 35). The skid type fuel system does not use the internal generator fuel tank.

Use the instructions in this section that applies to your type of fuel tank system.

ALWAYS fill the fuel tank with clean and fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Temperature Range

Type Oil

 

 

104° F ~ 23° F

SAE 15W-40

(40° C ~ -5°C)

 

 

 

23° F ~ 5° F

SAE 5W-30

(-5° C ~ -15°C)

 

 

 

Below 5° C (-15°)

SAE 30 OR SAE 0W-30

 

 

Figure 34. Double Fuel Tank System

WARNING:

ONLY properly trained personel who have read and understand this section should refill the double fuel tank system.

Use #2 diesel fuel.

PAGE 36 — DCA-125SSJU SERIES (STANDARD) — PARTS AND OPERATION MANUAL — REV. #4 (06/03/03)

Page 36
Image 36
Multiquip manual DCA-125SSJU Series PRE-SETUP, Circuit Breakers, Lubrication Oil, Refilling the Fuel System

DCA-125SSJU specifications

The Multiquip DCA-125SSJU is a robust and reliable diesel generator that stands out in the construction and rental markets. Designed to provide consistent power, this generator is ideal for various applications ranging from industrial construction sites to outdoor events. The DCA-125SSJU boasts a powerful 125 kVA output, making it suitable for both small and large power needs.

One of the prominent features of the DCA-125SSJU is its advanced engine technology. It is powered by a reliable and fuel-efficient Yanmar diesel engine. This engine not only ensures longevity but also optimizes fuel consumption, allowing operators to save on running costs without compromising performance. With a robust design, the Yanmar engine guarantees excellent cold start capability, making it dependable even under challenging weather conditions.

The generator's sound attenuation is also noteworthy. Encased in a sound-attenuated enclosure, the DCA-125SSJU operates at a noise level that makes it suitable for use in residential areas or environments with strict noise regulations. This feature enhances the generator's versatility, as it can be employed in various settings without disturbing nearby activities.

Multiquip has incorporated several safety features into the DCA-125SSJU, including automatic shutdown systems that activate in the event of low oil pressure or overheating. This proactive approach helps safeguard the engine and prolongs its lifespan. Additionally, the generator is equipped with a heavy-duty, weatherproof frame, ensuring durability and protection against the elements.

User-friendly control features make the DCA-125SSJU easy to operate. The generator includes an intuitive digital control panel that provides essential information such as voltage output, frequency, and run time. This accessibility allows operators to monitor performance and adjust settings as necessary.

Portability is another significant advantage of the DCA-125SSJU. With easily transportable dimensions, it can be efficiently moved to various job sites. Its sturdy wheels and lifting points further enhance mobility, making it a practical solution for temporary power needs.

In summary, the Multiquip DCA-125SSJU is a high-performance diesel generator, combining power, efficiency, and portability with advanced technology and user-friendly features. Its reliability and versatility make it an excellent choice for contractors, event organizers, and anyone in need of dependable power supply. Whether facing the demands of a construction site or hosting an outdoor function, the DCA-125SSJU ensures you’ll never be left in the dark.