DCA-125USJ (50 HZ)— GENERATOR START-UP PROCEDURE (MANUAL)

12.The engine oil pressure gauge (Figure 49) will indicate the oil pressure (kg/ cm2) of the engine. Under normal operating conditions the oil pressure is approximately 35~65 PSI.

Figure 49. Oil Pressure Gauge

13.The coolant temperature gauge (Figure 50) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 165 and 215 degrees Fahrenheit (Green Zone).

15.Place the main, GFCI, and aux. circuit breakers in the ON position (Figure 52).

Figure 50. Coolant Temperature Gauge

14.The tachometer gauge (Figure 51) will indicate the speed of the engine when the generator is operating. Under normal operating conditions this speed is approximately 1500 RPM’s.

Figure 51. Engine Tachometer Gauge

Figure 52. Main, Aux. and GFCI

Circuit Breakers (ON)

16.Observe the generator's ammeter (Figure 53) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if a load is in use.

Figure 53. Ammeter (Load)

17.The generator will run until manually stopped or an abnormal condition occurs.