CAUTION:

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the DCA-400SSK portable generator:

GENERAL SAFETY

DONOToperateorservicethisequipmentbefore reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

NEVERoperate this equipment when not feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence or drugs or alcohol.

NEVER use accessories or attachments, which are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

Manufacturer does not assume responsibility for any accident due to equipment modifications.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

Always check the machine for loosened threads or bolts before starting.

RULES FOR SAFE OPERATION

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generator.

High Temperatures – Allow the

engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

The engine of this generator requires an adequate free flow of cooling air. Never operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator or engine and may cause injury to people.The generator engine gives off DEADLY carbon monoxide gas.

CAUTION:

Always refuel in a well-ventilated area, away from sparks and open flames.

Always use extreme caution when working with flammable liquids.When refueling, stop the engine and allow it to cool. DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

Topping-off to filler port is dangerous, as it tends to spill fuel.

PAGE 6 — DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01)

Page 6
Image 6
Multiquip DCA-400SSK operation manual Rules for Safe Operation, High Temperatures Allow

DCA-400SSK specifications

The Multiquip DCA-400SSK is a robust solution designed for a variety of construction and developmental applications. Known for its reliability and efficiency, this three-phase diesel generator is equipped with a powerful engine that offers dependable performance in the field.

One of the standout features of the DCA-400SSK is its 400 kW output capacity, making it an ideal choice for large-scale operations where consistent power supply is crucial. It is powered by a high-performance, durable diesel engine that meets stringent emissions standards, ensuring compliance while delivering high efficiency.

The DCA-400SSK comes equipped with advanced technology that enhances its usability and performance. Its automatic voltage regulation (AVR) system ensures stable voltage under varying load conditions, which is essential for sensitive electrical equipment. This feature provides peace of mind to operators, knowing that their equipment is protected from voltage fluctuations.

Built with a sound-attenuated enclosure, the DCA-400SSK is designed to minimize noise, making it suitable for operation in noise-sensitive environments. This aspect not only protects the hearing of those working nearby but also ensures compliance with local noise regulations, thereby promoting a safer working environment.

Another remarkable characteristic of the DCA-400SSK is its user-friendly control panel, which features easy-to-read gauges and straightforward controls. This makes monitoring and operating the generator simple, even for those with limited experience in generator operation. With remote start capabilities, users can start and stop the generator from a distance, enhancing efficiency and convenience.

In terms of mobility, the DCA-400SSK is designed with integrated lifting points and forklift pockets, which facilitate easy transport around job sites. Its rugged construction ensures durability, able to withstand the harsh conditions typical of construction sites while maintaining optimal performance.

Overall, the Multiquip DCA-400SSK stands as a reliable and efficient diesel generator, combining powerful output with advanced features and environmental considerations. It is tailored to meet the demands of contractors and operators looking for a versatile and sturdy power solution. Whether for temporary power needs or long-term projects, the DCA-400SSK delivers exceptional performance in a compact and user-friendly package.