DCA-400SSK —TRAILER-BRAKETROUBLESHOOTING

Table 5. Electric Brake Troubleshooting

Symptom

Possible Cause

Solution

 

 

 

No Brakes or Intermittent

Any open circuits or broken wires?

Find and correct.

Brakes

 

 

Any short circuits?

Find and correct.

 

 

 

 

 

Faulty controller?

Test and correct.

 

 

 

 

Any loose connections?

Find and repair.

 

 

 

 

Ground wire secure?

Find and secure.

 

 

 

Weak Brakes or Brakes

Grease or oil on magnets or linings?

Clean or replace.

Pull to One Side

 

 

Connections corroded?

Clean and correct

 

 

 

cause of corrosion.

 

 

 

 

Brake drums scored or grooved?

Machine or replace.

 

 

 

 

Brakes synchronized?

Correct.

 

 

 

Locking Brakes

Brake components loose, bent or

Replace components.

 

broken?

 

 

 

 

 

Brake drums out-of-round?

Replace.

 

 

 

Noisy Brakes

System lubricated?

Lubricate.

 

 

 

 

Brake components correct?

Replace and correct.

 

 

 

Dragging Brakes

Bearings of the wheel adjusted?

Adjust.

 

 

 

DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01) — PAGE 19

Page 19
Image 19
Multiquip operation manual DCA-400SSK -TRAILER-BRAKETROUBLESHOOTING, Symptom Possible Cause Solution

DCA-400SSK specifications

The Multiquip DCA-400SSK is a robust solution designed for a variety of construction and developmental applications. Known for its reliability and efficiency, this three-phase diesel generator is equipped with a powerful engine that offers dependable performance in the field.

One of the standout features of the DCA-400SSK is its 400 kW output capacity, making it an ideal choice for large-scale operations where consistent power supply is crucial. It is powered by a high-performance, durable diesel engine that meets stringent emissions standards, ensuring compliance while delivering high efficiency.

The DCA-400SSK comes equipped with advanced technology that enhances its usability and performance. Its automatic voltage regulation (AVR) system ensures stable voltage under varying load conditions, which is essential for sensitive electrical equipment. This feature provides peace of mind to operators, knowing that their equipment is protected from voltage fluctuations.

Built with a sound-attenuated enclosure, the DCA-400SSK is designed to minimize noise, making it suitable for operation in noise-sensitive environments. This aspect not only protects the hearing of those working nearby but also ensures compliance with local noise regulations, thereby promoting a safer working environment.

Another remarkable characteristic of the DCA-400SSK is its user-friendly control panel, which features easy-to-read gauges and straightforward controls. This makes monitoring and operating the generator simple, even for those with limited experience in generator operation. With remote start capabilities, users can start and stop the generator from a distance, enhancing efficiency and convenience.

In terms of mobility, the DCA-400SSK is designed with integrated lifting points and forklift pockets, which facilitate easy transport around job sites. Its rugged construction ensures durability, able to withstand the harsh conditions typical of construction sites while maintaining optimal performance.

Overall, the Multiquip DCA-400SSK stands as a reliable and efficient diesel generator, combining powerful output with advanced features and environmental considerations. It is tailored to meet the demands of contractors and operators looking for a versatile and sturdy power solution. Whether for temporary power needs or long-term projects, the DCA-400SSK delivers exceptional performance in a compact and user-friendly package.