OUTPUT TERMINAL PANEL CONNECTIONS

OUTPUT TERMINAL PANEL CONNECTIONS

UVWO TERMINAL OUTPUT VOLTAGES

Various output voltages can be obtained using the UVWO output terminal lugs. The voltages at the terminals are dependent on the position of the Voltage Selector Switch and the adjustment of the Voltage Regulator Control Knob.

Remember the voltage selector switch determines the range of the output voltage. The voltage regulator (VR) allows the user to increase or decrease the selected voltage.

3Ø-220/127 UVWO Terminal Output Voltages

1.Place the voltage selector switch in the 3Ø 240/139 position as shown in Figure 18..

Figure 18. Voltage Selector Switch

3Ø-240/139V Position

2.Connect the load wires to the UVWO terminals as shown in Figure 19.

Figure 19. UVWO Terminal Lugs

3Ø-220/127V Connections

3.Turn the voltage regulator knob (Figure 20) clockwise to increase voltage output, turn counterclockwise to decrease voltage output. Use voltage regulator adjustment knob whenever fi ne tuning of the output voltage is required.

Figure 20. Voltage Regulator Knob

3Ø-200V/1Ø-115V UVWO Terminal Output Voltages

1.Place the voltage selector switch in the 3Ø 240/139 position as shown in Figure 21.

Figure 21. Voltage Selector Switch

3Ø-240/139V Position

2.Connect the load wires to the UVWO terminals as shown in Figure 22.

Figure 22. UVWO Terminal Lugs

3Ø-200/1Ø-115V Connections Connections

NOTICE

To achieve a 3Ø 200V output the voltage selector switch must be in the 3Ø-240/139 position and the voltage regulator must be adjusted to 200V..

PAGE 28 — DCA125SSIU 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (12/22/08)

Page 28
Image 28
Multiquip DCA125SSIU manual Output Terminal Panel Connections, Uvwo Terminal Output Voltages, Notice