DCA-180SSK —TROUBLESHOOTING (GENERATOR/ENGINE)

Practically all generator breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the

diagnosed based on the Generator Troubleshooting (Table

17)and the MPEC troubleshooting (Table 18) information shown . If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 17. ENGINE & GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Dead battery?

Replace battery.

Engine fails to start and

 

 

Defective starter switch?

Replace switch.

starter does not rotated.

 

 

 

Fuse F5 burned out?

Replace fuse.

 

 

 

 

Broken pre-heat circuit?

Check pre-heat circuit.

Engine fails to start and

 

 

No fuel?

Add fuel.

starter rotates.

 

 

 

Defective wiring?

Check wiring.

 

 

 

 

Clogged fuel strainer?

Clean or replace.

Engine starts and remains at

 

 

Clogged air cleaner?

Clean or replace.

low speed.

 

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

No voltage present in AC

Replace rectifier (RE1).

 

power source?

 

 

 

 

 

Engine speed rises and no

Defective rotor?

Replace rotor.

 

 

Defective voltmeter?

Replace voltmeter.

voltage is present in AC

power source.

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

 

Layer short-circuit in armature

Replace armature.

 

winding?

 

 

 

 

 

Engine speed rises and AC

Defective circuit breaker

Replace circuit breaker (protector).

(protector)?

 

power voltage is too low or

 

 

Layer short-circuit, broken

 

cannot be used.

Repair or replace armature.

 

wires in armature winding?

 

 

 

 

 

Engine speed rises and

Defective engine regulator?

Replace regulator.

 

 

battery discharges too soon.

Defective wiring?

Repair or replace wiring.

 

 

 

Engine speed rises and

Defective alternator?

Repair or replace alternator.

 

 

engine seems overloaded.

Damaged alternator bearing?

Replace alternator bearings.

 

 

 

 

PAGE 62 — DCA-180SSK — PARTS AND OPERATION MANUAL — REV. #3 (06/11/09)

Page 62
Image 62
Multiquip DCA180SSK DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINE, Diagnosed based on the Generator Troubleshooting Table

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.