1.Oil Pressure Gauge — During normal operation this gauge should read between 35 to 65 psi. (241~448 kPa). When starting the generator the oil pressure may read a little higher, but after the engine warms up the oil pressure should return to the correct pressure range.

2.WaterTemperature Gauge — During normal operation this gauge be should read between 180°~221°F (82°~105°C)

3.Charging Ammeter Gauge — Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

4.Fuel Gauge — Indicates amount of diesel fuel available.

5.Tachometer — Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

6.Panel Light — Normally used in dark areas or at night time. When activated, panel lights will illuminate. When the generator is not in use be sure to turn the panel light switch to the OFF position.

7.Panel Light Switch — When activated will turn on control panel light.

8.Fuel Filter Water Level Alarm Lamp — This lamp will illuminate when water in the fuel filter has reached an abnormal level.

9.Auto START/STOP Engine Controller (ECU) —This controller has a vertical row of status LED's (inset), that when lit, indicate that an engine malfunction (fault) has been detected. When a fault has been detected the engine controller will evaluate the fault and all major faults will shutdown the generator. During cranking

cycle, the ECU will attempt to crank the engine for 10 seconds before disengaging.

If the engine does not engage (start) by the third attempt, the engine will be shutdown by the engine controller’s Over Crank Protection mode. If the engine engages at a speed (RPM's) that is not safe, the controller will shutdown the engine by initializing the Over Speed Protection mode.

Also the engine controller will shut down the engine in the event of low oil pressure, high coolant temperature, low coolant level, and loss of magnetic pickup. These conditions can be observed by monitoring the LED status indicators on the front of the controller module.

A.MPEC Control Switch — This switch controls the running of the unit. If this switch is set to the OFF/ RESET position, the unit will not run. When this switch is set to the manual position, the generator will start immediately.

If the generator is to be connected to a building’s AC power source via an automatic transfer switch (isolation), place the switch in the AUTO position. In this position, should an outage occur, the automatic transfer switch (ATS) will start the generator automatically via the generator’s auto-start contacts connected to the ATS’s start contacts. Please refer to your ATS installation manual for further instructions for the correct installation of the auto-start contacts of the generator to the ATS.

B.Low Oil Pressure — Indicates the engine pressure has fallen below 15 psi (103 kPa). The oil pressure is detected using variable resistive values from the oil pressure sending unit.This is considered a major fault.

C.High Coolant Temperature — Indicates the engine temperature has exceeded 230°F (110°C).The engine temperature is detected using variable resistive values from the temperature sending unit. This is considered a major fault.

D.Overcrank Shutdown — Indicates the unit has attempted to start a pre- programmed number of times, and has failed to start.The number of cycles and duration are programmable. It is pre-set at 3 cycles with a 10 second duration. This is considered a major fault.

E.Overspeed Shutdown — Indicates the engine is running at an unsafe speed. This is considered a major fault.

F.Engine Running — Indicates that engine is running at a safe operating speed.

DCA20spxu2 servpro® • operation and parts manual — rev. #0 (09/23/13) — page 21

Page 21
Image 21
Multiquip DCA20spxu2 manual Engine control Panel

DCA20spxu2 specifications

The Multiquip DCA20SPXU2 is a powerful and versatile portable generator that has become a favorite among contractors and outdoor enthusiasts alike. Designed for reliability and efficiency, this unit boasts a range of features that make it suitable for various applications, from construction sites to recreational activities.

One of the standout characteristics of the DCA20SPXU2 is its robust engine. Powered by a reliable 20 kW diesel engine, this generator offers ample power to run essential tools and equipment, ensuring that users can depend on it for demanding tasks. The engine is not only powerful but also designed for fuel efficiency, helping users save on operating costs during extended use.

The DCA20SPXU2 features an impressive run time, with a large fuel tank that enables it to operate for long periods without requiring frequent refueling. This is particularly beneficial for projects that are located in remote areas or for outdoor events where electricity is critical.

Another key highlight of the DCA20SPXU2 is its advanced sound attenuation design. This generator operates quietly, adhering to stringent noise regulations, which is essential when working in residential or noise-sensitive environments. The sound-dampening technology helps to minimize sound levels, making it an excellent choice for events and job sites that demand a quieter operation.

Multiquip has also integrated a user-friendly control panel in the DCA20SPXU2, featuring intuitive gauges and indicators that provide vital information at a glance, such as fuel levels, output voltage, and operational status. This ease of use allows operators to quickly monitor performance and make necessary adjustments.

The generator is equipped with multiple outlets, including 120V and 240V options, ensuring that it can power a variety of tools and equipment simultaneously. This versatility enhances its appeal for users who require flexibility in their power source.

Durability is another hallmark of the DCA20SPXU2. Built with high-quality materials, the generator is designed to withstand tough conditions, making it an ideal companion for construction sites or outdoor adventures.

In conclusion, the Multiquip DCA20SPXU2 is a well-engineered portable generator that offers a blend of power, efficiency, and convenience. With its robust engine, quiet operation, user-friendly controls, and durable construction, it stands out as a reliable choice for both professional and recreational use, meeting the power needs of a variety of users.