inspection/SETUP

Circuit Breakers

To protect the generator from an overload, a 3-pole, 60 amp, main circuit breaker is provided to protect the U,V, and W Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload.Three 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level and verify that the oil level is maintained between the two notches (Figure 28) on the dipstick. See Table 11 for proper selection of engine oil.

Figure 28. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the ISUZU Engine Owner’s Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

„„ API Service Classification CC/SC

„„API Service Classification CC/SD

„„API Service Classification CC/SE

„„API Service Classification CC/SF

Table 11. Recommended Motor Oil

Fuel Check

DANGER

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION

ONLY properly trained personnel who have read and understand this section should refill the fuel tank system.

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an environmental fuel tank (Figure 29). ALWAYS fill the fuel tanks with clean fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel. The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 29. Internal Fuel Tank System

page 28 — DCA25Usi2 60 hz Generator • operation and parts manual — rev. #0 (02/14/14)

Page 28
Image 28
Multiquip dca25USI2 manual Inspection/SETUP, Circuit Breakers, Lubrication Oil, Fuel Check, Refilling the Fuel System

dca25USI2 specifications

The Multiquip DCA25USI2 is a powerful and versatile portable generator designed for a range of applications in construction, events, and emergency power supply. This model is particularly noted for its durability and reliability, making it an excellent choice for both professionals and DIY enthusiasts.

At the heart of the DCA25USI2 is a robust 25 kW output, giving users plenty of power to run multiple tools, equipment, or systems simultaneously. This generator operates on a powerful water-cooled diesel engine, which not only enhances fuel efficiency but also extends the lifecycle of the machine compared to traditional gas-powered generators. The use of diesel fuel contributes to lower operational costs and makes it suitable for longer usage periods, particularly in remote locations.

One of the standout features of the DCA25USI2 is its compact design. Despite its high power output, this generator maintains a relatively small footprint, allowing for easy transportation and storage. Weighing around 1,800 pounds, it is fitted with a robust frame that provides durability while facilitating easy placement at job sites or outdoor events.

The generator is equipped with advanced noise reduction technology, ensuring that it operates quietly, which is crucial when working in residential areas or noise-sensitive environments. The sound-dampening enclosure significantly lowers operating noise levels, enhancing the overall user experience.

In terms of electrical output, the DCA25USI2 offers multiple options, including both single-phase and three-phase connections. This versatility allows users to power a variety of applications without needing additional adaptors. Moreover, the generator’s heavy-duty alternator ensures stable power delivery, protecting sensitive electronic devices from voltage spikes.

Another key characteristic of the DCA25USI2 is its user-friendly control panel, which features intuitive gauges and circuit breakers for easy management of power distribution. The panel includes a digital hour meter, allowing operators to track usage and plan for maintenance efficiently.

Safety features are also a priority with the DCA25USI2, including automatic shutdown capabilities to protect the engine against low oil levels and overheating. This thoughtful design helps to ensure both the performance and longevity of the generator.

In summary, the Multiquip DCA25USI2 stands out for its powerful output, efficient diesel engine, compact design, and advanced features, making it a top choice for anyone in need of reliable portable power. Whether for construction, events, or emergency backup, this generator is engineered to deliver exceptional performance and peace of mind.