Multiquip dca25USI2 manual Coolant Antifreeze/Summer Coolant/ Water, Operation in Freezing Weather

Models: dca25USI2

1 78
Download 78 pages 14.45 Kb
Page 30
Image 30

inspection/SETUP

Coolant (Antifreeze/Summer Coolant/ Water)

ISUZU recommends ISUZU antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted.See the ISUZU Engine Owner’s Manual for further details.

WARNING

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank.When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 12 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the “H” and the “L” markings.

Table 12. Coolant Capacity

Engine and Radiator

1.70 gal (6.4 liters)

Reserve Tank

2 quarts (1.9 liters)

Operation in Freezing Weather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 13) has been added.

Table 13. Anti-Freeze Operating Temperatures

Vol %

Freezing Point

Boiling Point

Anti-

 

 

 

 

°C

°F

°C

°F

Freeze

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTICE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the ISUZU Engine Owner’s Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

ISUZU Engine Owner’s Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 34) when depressed with the thumb as shown below.

Figure 34. Fan Belt Tension

CAUTION

NEVER place hands near the belts or fan while the generator set is running.

page 30 — DCA25Usi2 60 hz Generator • operation and parts manual — rev. #0 (02/14/14)

Page 30
Image 30
Multiquip dca25USI2 manual Coolant Antifreeze/Summer Coolant/ Water, Operation in Freezing Weather, Cleaning the Radiator

dca25USI2 specifications

The Multiquip DCA25USI2 is a powerful and versatile portable generator designed for a range of applications in construction, events, and emergency power supply. This model is particularly noted for its durability and reliability, making it an excellent choice for both professionals and DIY enthusiasts.

At the heart of the DCA25USI2 is a robust 25 kW output, giving users plenty of power to run multiple tools, equipment, or systems simultaneously. This generator operates on a powerful water-cooled diesel engine, which not only enhances fuel efficiency but also extends the lifecycle of the machine compared to traditional gas-powered generators. The use of diesel fuel contributes to lower operational costs and makes it suitable for longer usage periods, particularly in remote locations.

One of the standout features of the DCA25USI2 is its compact design. Despite its high power output, this generator maintains a relatively small footprint, allowing for easy transportation and storage. Weighing around 1,800 pounds, it is fitted with a robust frame that provides durability while facilitating easy placement at job sites or outdoor events.

The generator is equipped with advanced noise reduction technology, ensuring that it operates quietly, which is crucial when working in residential areas or noise-sensitive environments. The sound-dampening enclosure significantly lowers operating noise levels, enhancing the overall user experience.

In terms of electrical output, the DCA25USI2 offers multiple options, including both single-phase and three-phase connections. This versatility allows users to power a variety of applications without needing additional adaptors. Moreover, the generator’s heavy-duty alternator ensures stable power delivery, protecting sensitive electronic devices from voltage spikes.

Another key characteristic of the DCA25USI2 is its user-friendly control panel, which features intuitive gauges and circuit breakers for easy management of power distribution. The panel includes a digital hour meter, allowing operators to track usage and plan for maintenance efficiently.

Safety features are also a priority with the DCA25USI2, including automatic shutdown capabilities to protect the engine against low oil levels and overheating. This thoughtful design helps to ensure both the performance and longevity of the generator.

In summary, the Multiquip DCA25USI2 stands out for its powerful output, efficient diesel engine, compact design, and advanced features, making it a top choice for anyone in need of reliable portable power. Whether for construction, events, or emergency backup, this generator is engineered to deliver exceptional performance and peace of mind.