components (generator)
10
11
12
20
13
14 15
18
16
17
19
Figure 4. Generator Components (continued)
10.Spark Plug – Provides spark to the ignition system. Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean spark plug once a week.
11.Muffler/Heat Shield – Used to reduce noise and emissions. NEVER touch this heat shield when the generator/welder is in use. Always allow time for engine to cool before servicing.
12.Air Cleaner – Prevents dirt and other debris from entering the fuel system. Remove
13.Fuel Tank Cap – Remove this cap to add unleaded gasoline to the fuel tank. Replenish with clean unleaded gasoline. Make sure cap is tightened securely. DO NOT over fill
14.Choke Lever – Used for starting the engine. Close the choke lever when starting a cold engine or in cold weather conditions. The choke enriches the fuel mixture. Open the choke lever if starting a warm engine or in warm weather conditions
15.Fuel Cock Lever – Turn this lever downward to start (down)the flow of fuel into the carburetor. Turn upward to stop (up) the flow of fuel.
16.Engine Oil Filler Cap – Remove this cap/dipstick when the adding of engine oil is required. See Table 4 for recommended type engine oil.
17.Engine Oil Drain Plug – Remove this drain plug when draining of the oil from the engine crankcase is required. Fill with recommeded type oil as listed in Table 4.
18.Recoil Starter (pull rope) –
19.Fuel Gauge – This gauge is located on top of the fuel tank. Read this gauge to determine when fuel is low.
20.Fuel Tank – Fuel tank capacity is 5 gallons (19 liters)
NOTICE
This HONDA engine is equipped with a low oil shutdown capability. A built in sensor will automatically turn off the engine should the oil level fall below a safe operating condition. Make sure the generators is placed on level ground. Placing the generators on level ground will ensure that the low oil sensor will function properly.
page 18 — GAC6HZR 60 hz gENERATOR• operation and parts manual — rev. #1 (03/31/10)