Multiquip GAC-6HZR manual operation, Idle Control Switch OFF, Idle Control switch ON

Models: GAC-6HZR

1 82
Download 82 pages 20.5 Kb
Page 22
Image 22
Figure 15. Idle Control Switch (OFF)

operation

6.If the engine has started, slowly return the choke lever (Figure 12) to the OPEN position. If the engine has not started repeat steps 1 through 5.

7.Before the generator is placed into operation, run the engine for 3-5 minutes. Check for abnormal smells, fuel leaks, and noises that would associate with lose components.

8.Place idle control switch (Figure 15) in the OFF (down) position.This will allow the engine speed to run at about 3600 RPM's.

Figure 15. Idle Control Switch (OFF)

Figure 16. Idle Control switch (ON) NOTICE

Placing the idle control switch in the OFF position (Figure 15) allows the engine to operate at a maximum speed of about 3600 RPM's.

When the idle control switch (Figure 16) is placed in the up position (ON), the generator will run at idle speed (2200 RPM's) until a load is applied, at that time the engine speed will increase to 3600 RPM's as long as a load is being applied.

When the load is not in use, the engine speed will drop back to the idle mode after about 3 seconds.

Figure 16. Idle Control switch (ON)

9.Place main circuit breaker (Figure 19) in the ON position.

Figure 17. Main Circuit Breaker (ON)

10.Place GFCI circuit breaker (Figure 19) in the ON position.

Figure 18. GFCI Circuit Breaker (ON)

11.Read voltmeter on front panel of generator (Figure 19) and verify that 120 VAC is displayed. Using an external voltmeter as shown in Figure 19, verify that 120 VAC is present at the 120V twist-lock and GFCI duplex receptacles. .

Figure 19. 120V/GFCI Receptacles

page 22 — GAC6HZR 60 hz gENERATOR• operation and parts manual — rev. #1 (03/31/10)