maintenance

REPLACING LAMP

DANGER

Never attempt to replace lamp in a wet place. The possibility exists of electric shock.

WARNING

Always allow sufficient time for the lamp to cool down before replacing.The possibility exists of severe burns if hot lamp is touched.

\ CAUTION

Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp. Utmost care should be taken in handling broken lamp. The possibility exists of serious injury from handling a broken lamp.

1.Unzip the zipper at the bottom of the balloon and roll the balloon up to expose the lamp. See Figure 26.

BALLOON

ENVELOPE

ZIPPER

Figure 26. Exposing Balloon

2. Release the lamp guard locking tabs. See Figure 27.

LOCK

TAB

LAMP

GUARD

LOCK

TAB

Figure 27. Removing Lamp Guard

3. Remove the lamp guard (Figure 28).

LAMP

HOLDER

LAMP

GUARD

Figure 28. Lamp Guard Removal

4.Press tabs on the lamp holder and lift up holder to release lamp. Remove the lamp from the lamp socket by turning lamp counterclockwise. See Figure 29.

LAMP

SOCKET

Figure 29. Removing Lamp

5.Install new lamp into socket and turn lamp in a clockwise direction until tight. See Figure 30. Press tabs on the lamp holder and slowly bring down the holder to secure lamp in place.

LAMP

SOCKET

Figure 30. Installing New Lamp

page 24 — GBC lighting system • operation and parts manual — rev. #0 (06/24/13)

Page 24
Image 24
Multiquip GBC manual Maintenance, Replacing Lamp, Remove the lamp guard Figure