| maintenance | |
|
|
| |
|
|
| |
| Table 4. Troubleshooting |
| |
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
| Is plug disconnected? | Plug in correctly. | |
| Is generator power switched off? | Turn on switch. | |
| Is lamp loose? | Screw lamp securely into socket. | |
| Is power connector disconnected or | Connect disconnected connector. | |
| loose? | ||
|
| ||
Lamp does not light. | Are any other electric appliances |
| |
(other than light tower) plugged into | Unplug all other appliances. | ||
| |||
| power source? |
| |
| Is model of lamp incompatible? | Use genuine MQ lamp. | |
| Is lamp not cool enough to light |
| |
| again? (Interval of 5 to 10 minutes | Wait for lamp to cool down. | |
| is required before turning on lamp | ||
|
| ||
| again) |
| |
Lamp only lights for a short time. | Is ambient temperature too high | Move lamp where there is proper | |
(more than 104° F (40° C)? | ventilation. | ||
| |||
| Is fan motor (blower) not working | Check and repair fan motor (blower). | |
Balloon does not inflate. | properly? | ||
| |||
| Is balloon envelope defective? | Repair or replace balloon envelope. |