GLW-180H —WELDER OPERATING INSTRUCTIONS

Welding Cables and Polarities

Connect the welding cables (Figure 4) to the welder's output terminals located on the control panel. The output terminals have (+) and (-) polarities. Select the appropriate polarities according to the application (SeeWelding Application,Table 5).

NOTE

Attach terminal connectors at the end of each cable. NEVER connect exposed wires (Figure 5) directly to the terminal. Exposed wiring may cause shocks or di-electric breakdown from poor contact.

Figure 4. Welding Cable Connection

(Correct)

 

 

Figure 5. Welding Cable Connection

 

 

 

(Incorrect)

 

 

 

 

Table 4. Welding Applications

 

 

 

 

POLARITY

WELDING METHOD

 

TYPICAL APPLICATIONS

 

 

 

 

 

(+) ... Grounding (Base Metal)

 

Welding steel materials for general

Straight Polarity

 

structures, and thickness plates.

 

 

 

 

 

 

(-) ... Welder Holder

 

Arc welding for copper alloy

 

 

 

 

 

(+) ... Welder Holder

 

Build-up welding, ARC welding of

Reverse Polarity

 

thin plates

 

 

 

 

 

 

(+) ... Grounding (Base Metal)

 

Arc welding of stainless steel

 

 

 

 

Note: Reguarding the selection of the polarity in the CV charactertics, follow the instructions from the wire maker.

PAGE 18 — GLW-180H A.C. GENERATOR/WELDER — PARTS & OPERATION MANUAL — REV. #5 (03/14/05)

Page 18
Image 18
Multiquip GLW-180H operation manual Welding Cables and Polarities, Incorrect