maintenance

General maintenance practices are crucial to the performance and longevity of your trowel. This equipment requires routine cleaning, blade and trowel arm inspection, lubrication and V-belt inspection for wear and damage. Reference Table 5 and Table 6 for scheduled engine and trowel maintenance.

The following procedures, devoted to maintenance, can prevent serious trowel damage or malfunctioning.

NOTICE

Reference HONDA engine manual supplied with your trowel for more detailed engine maintenance and troubleshooting.

CAUTION

ALWAYS allow the engine to cool before servicing. NEVER attempt any maintenance work on a hot engine.

CAUTION

ALWAYS disconnect the spark plug wire from the spark plug and secure away from the engine before performing maintenance or adjustments on the machine.

WARNING

Some maintenance operations may require the engine to be run. Ensure

Engine Air Cleaner

DANGER

DO NOT use gasoline or low flash point solvents for cleaning the air cleaner, the possibility exists of fire or explosion which can cause damage to the equipment and severe bodily harm or even DEATH!

CAUTION

Wear protective equipment such as approved safety glasses or face shields and dust masks or respirators when cleaning air filters with compressed air.

This engine is equipped with a replaceable, high-density paper air cleaner element. See Figure 42 for air cleaner components.

1.Remove the air cleaner cover and foam filter element.

2.Tap the paper filter element several times on a hard surface to remove dirt, or blow compressed air not exceeding 30 psi (207 kPa, 2.1 kgf/cm2) through the filter element from the inside out. NEVER brush off dirt. Brushing will force dirt into the fibers. Replace the paper filter element if it is excessively dirty.

3.Clean foam element in warm, soapy water or nonflammable solvent. Rinse and dry thoroughly. Dip the element in clean engine oil and completely squeeze out the excess oil from the element before installing.

that the maintenance area is well ventilated. Gasoline engine exhaust contains poisonous carbon monoxide gas that can cause unconsciousness and may result in DEATH

General Cleanliness

Clean the trowel daily. Remove all dust and slurry buildup. If the trowel is steam-cleaned, ensure that lubrication is accomplished AFTER steam cleaning.

Engine check

Check daily for any oil and/or fuel leakage, thread nut and bolt tightness, and overall cleanliness.

AIR CLEANER

COVER

FOAM

FILTER

ELEMENT

PAPER

FILTER

ELEMENT

WING

NUT

WING

NUT

BLOW COMPRESSED

AIR FROM THE

INSIDE OUT

Figure 42. Engine Air Cleaner

page 30 — J36S60 WALK-BEHIND TROWEL • operation and parts manUAL — rev. #1 (01/23/13)

Page 30
Image 30
Multiquip J36S60 manual Engine Air Cleaner, General Cleanliness, Engine check

J36S60 specifications

The Multiquip J36S60 is a versatile and robust generator designed for various applications, ranging from construction sites to outdoor events. With a focus on reliable power and durability, the J36S60 is engineered to meet the demanding requirements of professionals and contractors alike.

At the heart of the J36S60 is its powerful engine, which provides a maximum output of 36 kVA. This generator is equipped with a 60Hz, 240V output, making it suitable for a wide range of equipment and tools. The J36S60 features a fuel-efficient design, allowing for extended run times that minimize downtime on job sites. It can operate for hours on end, ensuring that you have continuous power for critical tasks.

One of the standout features of the J36S60 is its state-of-the-art control panel. The intuitive control panel provides clear access to various functions, making it easy for users to monitor power output, fuel levels, and maintenance intervals. The panel includes circuit breakers, hour meters, and an easy-to-read digital display, ensuring that operators have all necessary information at their fingertips.

Additionally, the Multiquip J36S60 generator incorporates advanced technologies for noise reduction and fuel efficiency. Its innovative design includes sound-dampening materials and a high-capacity silencer, resulting in quieter operation compared to traditional generators. This feature makes it especially suitable for urban environments where noise regulations are strictly enforced.

The J36S60 is built with durability in mind. The heavy-duty steel frame and powder-coated finish ensure that it can withstand the rigors of demanding job sites and adverse weather conditions. Furthermore, the unit is designed for easy transport, with integrated lifting hooks and a compact design that allows for convenient positioning and relocation.

Safety is a priority with the J36S60, which comes equipped with multiple safety features including low oil shutdown, overload protection, and an emergency stop button. These safety mechanisms ensure that both the operator and the machinery are protected during operation.

Overall, the Multiquip J36S60 is a high-performance generator that excels in providing reliable power in a variety of settings. Its combination of power output, efficient fuel consumption, user-friendly controls, and robust build quality makes it an excellent choice for construction professionals, event coordinators, and anyone in need of dependable portable power.