DANGEROUS
GAS FUMES

Safety Information

TROWeL SaFeTy

DaNgeR

„Engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled.

„The engine of this equipment requires an adequate free fl ow of cooling air. NeveR operate this equipment in any enclosed or narrow area

where free fl ow of the air is restricted. If the air fl ow is

restricted it will cause injury to people and property and serious damage to the equipment or engine.

„NeveR operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

WaRNINg

„aLWayS keep clear of rotating or moving

parts while operating the trowel.

„DO NOT start or operate the trowel if the drive train will not disengage. Centrifugal

force between the trowel and surface when starting can cause uncontrolled handle movement that can cause serious injury. The handle must not move while pulling the engine recoil starter.

„NeveR disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CaUTION

„NeveR stand on trowel during operation.

„NeveR lubricate components or attempt service on a running machine.

„NeveR place your feet or hands inside the guard rings while starting or operating this equipment.

NOTICE

„aLWayS keep the machine in proper running condition.

„Fix damage to machine and replace any broken parts immediately.

„aLWayS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

„A safety manual for operating and maintenance personnel of concrete power trowels produced by the Association of Equipment Manufacturers (AEM) can be obtained for a fee by ordering through their website at www.aem.org.

Order FORM PT-160

eNgINe SaFeTy

WaRNINg

„DO NOT place hands or fingers inside engine compartment when engine is running.

„NeveR operate the engine with heat shields or guards removed.

„Keep fi ngers, hands hair and clothing away from all moving parts to prevent injury.

„DO NOT remove the radiator cap while the

engine is hot. High pressure boiling water will gush out of the radiator and severely scald any persons in the general area of the trowel.

„DO NOT remove the coolant drain plug while the engine is hot. Hot coolant will gush out of the coolant tank and severely scald any persons in the general area of the trowel.

„DO NOT remove the engine oil drain plug while the engine is hot. Hot oil will gush out of the oil tank and severely scald any persons in the general area of the trowel.

CaUTION

„NeveR touch the hot exhaust manifold, muffl er or cylinder. Allow these parts to cool

before servicing equipment.

j36s60 WALK-BEHIND TROWEL • operatION And parts manual — rev. #1 (01/23/13) — page 9

Page 9
Image 9
Multiquip J36S60 manual TROWeL SaFeTy, ENgINe SaFeTy, Order Form PT-160, Before servicing equipment

J36S60 specifications

The Multiquip J36S60 is a versatile and robust generator designed for various applications, ranging from construction sites to outdoor events. With a focus on reliable power and durability, the J36S60 is engineered to meet the demanding requirements of professionals and contractors alike.

At the heart of the J36S60 is its powerful engine, which provides a maximum output of 36 kVA. This generator is equipped with a 60Hz, 240V output, making it suitable for a wide range of equipment and tools. The J36S60 features a fuel-efficient design, allowing for extended run times that minimize downtime on job sites. It can operate for hours on end, ensuring that you have continuous power for critical tasks.

One of the standout features of the J36S60 is its state-of-the-art control panel. The intuitive control panel provides clear access to various functions, making it easy for users to monitor power output, fuel levels, and maintenance intervals. The panel includes circuit breakers, hour meters, and an easy-to-read digital display, ensuring that operators have all necessary information at their fingertips.

Additionally, the Multiquip J36S60 generator incorporates advanced technologies for noise reduction and fuel efficiency. Its innovative design includes sound-dampening materials and a high-capacity silencer, resulting in quieter operation compared to traditional generators. This feature makes it especially suitable for urban environments where noise regulations are strictly enforced.

The J36S60 is built with durability in mind. The heavy-duty steel frame and powder-coated finish ensure that it can withstand the rigors of demanding job sites and adverse weather conditions. Furthermore, the unit is designed for easy transport, with integrated lifting hooks and a compact design that allows for convenient positioning and relocation.

Safety is a priority with the J36S60, which comes equipped with multiple safety features including low oil shutdown, overload protection, and an emergency stop button. These safety mechanisms ensure that both the operator and the machinery are protected during operation.

Overall, the Multiquip J36S60 is a high-performance generator that excels in providing reliable power in a variety of settings. Its combination of power output, efficient fuel consumption, user-friendly controls, and robust build quality makes it an excellent choice for construction professionals, event coordinators, and anyone in need of dependable portable power.