Inspection and Maintenance Service Tables.

CAUTION :

Inspection and other services should ALWAYS be carried out on hard and level ground with the engine shutdown. These inspection intervals are for operation under normal conditions. Adjust your inspection

intervals based on the number hours plate compactor is in use, and particular working conditions.

Inspection and Maintenance Service Tables.

To make sure your plate compactor is always in good working condition before using, carry out the maintenance inspection in accordance with Tables 5 through 7.

TABLE 5. MVH-402GHB MACHINE INSPECTION

ITEM

HOURS OF

REMARKS

OPERATION

 

 

 

 

 

Loose or Missing

Every 8 hours

 

Screws

(every day)

 

 

 

 

Damaged Parts

Every 8 hours

 

(every day)

 

 

 

 

 

 

Function of Controlling

Every 8 hours

 

System Part

(every day)

 

 

 

 

Hydraulic System Leak

Every 100 hours

See page 22

 

 

 

Vibrator Oil Check

Every 100 hours

See page 22

 

 

 

Vibrator Oil

Every 300 hours

See page 22

Replacement

 

 

 

 

 

Hydraulic Oil Check

Every 100 hours

See page 23

 

 

 

Hydraulic Oil

First after 200

 

hours, then every

See page 23

Replacement

1,000 hours

 

 

 

 

 

 

V-belt (clutch) Check

Every 200 hours

See page 22

 

 

 

Battery Check

Every 100 hours

See page 23

 

 

 

CAUTION :

Fuel piping and connections should be replaced every 2 years.

MVH-402GHB — MAINTENANCE

Daily Service

zCheck for leakage of fuel or oil.

zCheck for loose screws including tightness. See Table 6 below (tightening torque ), for retightening:

zRemove soil and clean the bottom of compaction plate.

zCheck hydraulic pump, piping and hose for any leakage. A loosened hydraulic hose can be a cause for leakage. Check hydraulic hose connections with wrench applied for tightness.

zCheck engine oil.

TABLE 6. MVH-402GHB ENGINE CHECK

ITEM

HOURS OF OPERATION

 

 

Spark Plug Check

Every 40 hours (every week)

 

 

Oil or Fuel Leak

Every 8 hours (every day)

 

 

Tightness of Fastening

Every 8 hours (every day)

Threads

 

 

 

Engine Oil Check and

Every 8 hours (every day)

(Replenish to specified maximum

Replenishment

level)

 

 

 

Engine Oil Replacement

After first 25 hours then every 50 to

100 hours

 

 

 

Air Filter Cleaning

Every 100 hours

 

 

See separate engine manual for details on engine check.

TABLE 7.

TIGHTENING TORQUE (in. kg/cm) Diameter

Material

6mm

8mm

10mm

12mm

14mm

16mm

18mm

20mm

 

 

 

 

 

 

 

 

 

4T

70

150

300

500

750

1,100

1,400

2,000

 

 

 

 

 

 

 

 

 

6-8T

100

250

500

800

1,300

2,000

2,700

3,800

 

 

 

 

 

 

 

 

 

11T

150

400

800

1,200

2,000

2,900

4,200

5,600

 

 

 

 

 

 

 

 

 

*

100

300~

650 ~

 

 

 

 

 

350

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* (In case counter-part is of aluminum)

(Threads in use with this machine are all right handed)