Multiquip P33/24 HHMR operation manual Starting the engine

Models: P33/24 HHMR

1 39
Download 39 pages 14.99 Kb
Page 24
Image 24

Operation:

Note:

Desist from any method of operation which could pose a safety hazard or impair the static stability of the machine.

Never travel on sloping surfaces transversely, but always directly upwards or downwards.

Every time before starting up, always clean the transmitter and receiver elements.

For safety reasons, never deposit the transmitter near the machine. During breaks in work, the emergency stop switch must always be activated (Position „0“).

Should the transmitter be defective for any reason, switch off the machine immediately using the throttle lever „GH“.

iDanger

Before driving, check whether persons are located in the driving area. Damp and loose substrates substantially reduce the machine‘s grip on sloping

surface and inclines. When driving up slopes and inclines, the speed must be adjusted in line with the terrain. Never drive at high speed on slopes and inclines.

Remark:

The transmitter is fi tted with solar cells:

Steps must be taken to guarantee that the solar cells are not covered during and after operation, in order to guarantee automatic charging..

The solar cells must also be cleared of dirt, as otherwise automatic charging cannot be guaranteed.

5.3Starting the engine

When starting the engine, the starting conditions of the engine manufacturer must be observed.

16

1.Fill with fuel (see Maintenance section 9.6)

2.Move the throttle lever to the „Start“ position (Fig. 17).

3.All switching levers must be in the neutral position (Fig. 18).

4. Slip on the transmitter, move the emergency stop switch from the „N“ to the „I“ position (Fig. 19).

5.Press the Start/Stop switch „S“ (Fig. 16) to the left and hold until the engine starts.

17

 

 

18

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remark:

Do not actuate the start switch for longer than 15 secs. If the engine fails to start repeat the process.

For starting with jump leads, see section 7.0, page 28.

24

Page 24
Image 24
Multiquip P33/24 HHMR operation manual Starting the engine