Figure 2 shows a typical application using the QP305SLT/QPT305SLT centrifugal pump. Please note that this pump is intended for the removal of clean water.

Figure 2. QP305SLT/QPT305SLT Pump Application

1.Discharge Port 1.5-InchConnect a flexible rubber hose to this 1.5-inch discharge port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type discharge hose. Contact Multiquip Parts Department for ordering information.

2.Discharge Port 1-InchConnect a flexible rubber hose to these 1-inch discharge ports on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type discharge hose. Contact Multiquip Parts Department for ordering information.

3.Fill Cap — Prior to operation, the pump casing should be filled with water. Remove this cap to add water to the pump. After the initial prime, a sufficient amount of water will be retained in the casing so that the operator will not need to re-prime later.

4.Worm Clamp — Used to secure the hose to the inlet and outlet ports on the pump. Use two clamps to secure the hose on the inlet side of the pump.

5.Discharge Hose — Connect a flexible rubber hose to the discharge port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type discharge hose. Contact Multiquip Parts Department for ordering information.

6.Pump — The model QP305SLT/QPT305SLT is a 3-inch high pressure centrifugal pump and should only be used in clear water applications (agricultural, industrial, residential) as they have a limited soild handling capability of only 10% by volume.

7.Drain Plug — Remove this plug to drain water from the pump.

8.Suction Hose — Connect a flexible rubber hose to the suction port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type suction hose. Contact Multiquip Parts Department for ordering information.

9.Strainer — Always attach a strainer to bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water. Running the pump with the strainer above water for long periods can damage pump.

QP305SLT/QPT305SLT CENTRIFUGAL PUMP • operation and parts manual — rev. #1 (10/11/10) — page 13