OPERATION
CAUTION
DO NOT attempt to operate the pump until the Safety, General Information and Inspection sections of this manual have been read and thoroughly understood.
This section is intended to assist the operator with the initial
Starting the Engine (HONDA)
1.Place the engine fuel valve lever (See Figure 6) to the “ON” position.
Figure 6. Engine Fuel Valve Lever (ON Position)
2.Move the throttle lever (See Figure 7) away from the slow position, about 1/3 of the way toward the fast position.
3.Place the choke lever (See Figure 8) in the “CLOSED” position if starting a cold engine.
Figure 8. Engine Choke Lever (Closed)
4.Place the choke lever (See Figure 9) in the “OPEN” position if starting a warm engine or the temperature is warm.
Figure 9. Engine Choke Lever (Open)
5.Place the engine ON/OFF switch (See Figure 10) in the “ON” position.
Figure 7. Throttle Lever (1/3 Start Position)
Figure 10. Engine ON/OFF Switch (ON Position)
QP305SLT/QPT305SLT CENTRIFUGAL PUMP • operation and parts manual — rev. #1 (10/11/10) — page 17