S-500 SERIES SUB. PUMP — MAINTENANCE
LUBRICATION
To check the oil level of the mechanical seal perform the following:
DISASSEMBLY
Refer to Figure 11 for location of parts to be removed.
1.Position pump upside down.
2.Remove strainer.
3.Remove casing.
2.While checking the hydraulic oil level, also check the condition of the hydraulic oil in the seal cavity . Block the opening with a finger and roll pump to one side to drain oil into a small transparent container.If oil is cloudy or has water in it, drain oil from pump cavity and replace hydrau- lic oil. Check the seal for wear damage.
3.If oil level is low fill with SAE 10 weight
IMPELLER
4. Remove the pump impeller.
1.
5.Remove the liner.
6.Remove the oil plug and packing.
2.
OIL CHECK
1.Visually inspect oil plug hole to verify that oil cavity is full enoughtocoversealspring.Checkevery300hours,change hydraulic oil every 6 months (1,000 hours) or as needed.
Make sure the clearance between the impeller and the friction disk is approximately .012
.508 mm.)
If impeller is defective or badly worn, replace impeller imme- diately.
REMOVE FILL PLUG, AND VISUALLY INSPECT THAT
OIL CAVITY IS FULL ENOUGH TO COVER SEAL SPRING.
FILL TO
FILL WITH 10 WEIGHT NON- DETERGENT HYDRAULIC OIL. USE SHELL TURBO 32 OR EQUIVALENT.
CHECK HYDRAULIC OIL EVERY 300 HOURS. CHANGE EVERY 6 MONTHS OR AS NEEDED.
DISCOLORATION OF OIL (MILKY) INDICATES A LEAKING PUMP WATER SEAL.
STEP 2
REMOVE STRAINER
STEP 3
REMOVE
POSITION
STEP 1 PUMP UPSIDE DOWN
CASING
STEP 4
REMOVE
IMPELLER
STEP 5
REMOVE
LINER
STEP 6 |
|
REMOVE |
|
OIL PLUG |
|
AND |
|
PACKING | OIL |
| |
CASING | CAVITY |
| |
COVER |
|