PAGE 46 — TLG-12SPX — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/08/05)

GNITOOHSELBUORTROTARENEG.71ELBAT

MOTPMYS MELBORPELBISSOP NOITULOS
tuptuOegatloVoN
?evitcefedretemtloVCA .retemtlovagnisuegatlovtuptuokcehC
?esoolnoitcennocgniriwsI .riaperdnagniriwkcehC
?evitcefedRVAsI .yrassecenfiecalpeR
?reifitceRgnitatoRevitcefeD .ecalperdnakcehC
tuptuOegatloVwoL
?tcerrocdeepsenignesI ."hgiH"otrevelelttorhtenignenruT
?esoolsnoitcennocgniriwsI .riaperdnagniriwkcehC
?RVAevitcefeD .yrassecenfiecalpeR
tuptuOegatloVhgiH
?esoolsnoitcennocgniriwsI .riaperdnagniriwkcehC
?RVAevitcefeD .yrassecenfiecalpeR
deppirTrekaerBtiucriC
?daolnitiucriCtrohS .riaperdnadaolkcehC
?tnerrucrevO .ecuderdnastnemeriuqerdaolmrifnoC
?rekaerbtiucricevitcefeD .ecalperdnakcehC
?detautcayaleRtnerrucrevO .ecalperdnatnemeriuqerdaolmrifnoC

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a

breakdown, use the tables shown for diagnosis based on the Engine and Generator Troubleshooting (Table 12). If the

problem cannot be remedied, consult our company's business office or service plant.

TLG-12SPX — TROUBLESHOOTING (GENERATOR)